The Microlife 3AC1-PCCOS is an upper arm blood pressure monitor featuring clinically validated accuracy, one-touch operation, irregular heartbeat detection, 2-user memory with 99 readings each, WHO blood pressure classification indicator, body movement detection, and an easy-to-read large LCD display. It is designed for home use to help monitor and manage cardiovascular health. Below are key sections for safety, features, setup, operation, and maintenance.
Key components: Main unit with LCD display, Upper Arm Cuff, AC Adapter, Instruction Manual, Quick Start Guide, and Storage Case.
| Feature | Description |
|---|---|
| Clinically Validated Accuracy | Meets international protocols for accuracy and reliability |
| One-Touch Operation | Simple START/STOP button for easy measurement |
| Irregular Heartbeat Detection (IHD) | Detects and indicates possible pulse irregularities during measurement |
| 2-User Memory (99 readings each) | Stores readings separately for two users with date and time stamp |
| WHO Classification Indicator | Color-coded bar graph shows if reading is optimal, normal, or hypertensive |
| Body Movement Detection | Alerts user if movement during measurement may affect accuracy |
| Large LCD Display | Easy-to-read backlit screen showing systolic, diastolic, pulse, and date/time |
| Automatic Power Off | Conserves battery life by turning off after 1 minute of inactivity |
| AC Adapter Compatible | Can be powered by included AC adapter or 4xAA batteries |
| Average Value Calculation | Automatically calculates average of last 3 readings taken within 10 minutes |
Read all instructions before use. This device is for home monitoring only, not for medical diagnosis.
WARNING! This device is not a substitute for professional medical advice. Always consult your physician for diagnosis and treatment.
Note: Batteries (4xAA) are not included. Use alkaline batteries only.
Front Panel: LCD Display, START/STOP Button, MEMORY Button, USER Button (1/2), DATE/TIME Set Button.
Display Symbols: Systolic Pressure, Diastolic Pressure, Pulse Rate, WHO Indicator Bar, User Icon (1/2), Memory Icon, Irregular Heartbeat Symbol, Body Movement Symbol, Low Battery Icon, Date/Time.
Side/Back: Cuff Socket, AC Adapter Socket, Battery Compartment (requires 4xAA batteries).
Cuff: Marked with ARTERY index line. Ensure this line aligns with brachial artery on inner arm.
Before first use: Install batteries or connect AC adapter, set date/time, and select user.
CAUTION! Do not mix old and new batteries. Remove batteries if device will not be used for extended period.
For accurate results, rest for 5 minutes before measuring. Sit in a quiet place with back supported and feet flat on floor.
Tip: Take measurements at the same time each day, before medication, for consistent tracking.
The display shows three main values and indicators:
WHO Indicator Bar: Color-coded bar on right side of display: Green (Optimal: <120/80), Yellow (Normal: 120-129/80-84), Orange (High Normal: 130-139/85-89), Red (Hypertension: ≥140/90).
Symbols: Irregular Heartbeat symbol ( ) appears if irregular pulse detected during measurement. Body Movement symbol ( ) appears if excessive movement detected.
Note: A single high reading is not necessarily cause for alarm. Consult your physician if consistently high or if symptoms occur.
The device stores 99 readings for each of two users, with date and time stamp.
Note: Memory is maintained when batteries are replaced if done within 3 minutes.
Proper care ensures accurate measurements and extends device life.
CAUTION! Do not disassemble or attempt to repair device. No user-serviceable parts inside.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display when button pressed | Dead batteries, loose connection | Replace batteries; ensure AC adapter is firmly connected. |
| Error Code "E" appears | Cuff not connected, air leak | Check cuff connection; ensure cuff is properly applied without leaks. |
| Error Code "Err" | Measurement error | Restart measurement; ensure proper posture and stillness. |
| Inconsistent readings | Improper cuff position, movement | Reapply cuff correctly; remain still during measurement. |
| Memory not saving | Memory full, user not selected | Clear memory for current user; ensure correct user is selected. |
| Irregular Heartbeat symbol flashes | Possible arrhythmia detected | Consult physician if symbol appears frequently. |
Reset: Remove batteries and AC adapter for 5 minutes, then reconnect.
Support: For technical assistance or service, contact Microlife Customer Service at 1-800-435-XXXX or visit www.microlife.com.