The Microlife aponorm Professional is a clinically validated, automatic upper arm blood pressure monitor designed for professional and personal use. It features advanced PAD technology for accurate arrhythmia detection, one-touch operation, large memory storage, adjustable cuff, clear LCD display with hypertension indicator, and WHO classification. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.
Key components: Main unit with LCD display, adjustable arm cuff, air tube, AC adapter (optional), batteries, storage case, and user manual.
| Feature | Description |
|---|---|
| PAD Technology | Detects pulse arrhythmia during measurement |
| One-Touch Operation | Automatic inflation and deflation with single button |
| Memory Function | Stores up to 99 readings with date/time stamp |
| WHO Classification | Color-coded indicator for blood pressure evaluation |
| Adjustable Cuff | Fits arm circumferences 22-42 cm (9-16.5 inches) |
| Large LCD Display | Clear readings for systolic, diastolic, pulse, and time |
| Hypertension Indicator | Alerts if reading exceeds WHO standard |
| Automatic Power Off | Conserves battery life |
| Dual Power Source | Operates on 4xAA batteries or AC adapter |
| Clinically Validated | Meets accuracy standards of major medical associations |
Read all instructions before use. Keep for future reference.
WARNING! This device is not a substitute for professional medical diagnosis. Always consult your doctor about your blood pressure.
CAUTION! Inspect all components before use. Do not use if damaged.
Front Panel: START/STOP button, Memory (M) button, Date/Time (D/T) button, LCD display. Cuff: Air tube connection point, Velcro closure, artery marker. Rear: Battery compartment, AC adapter socket.
Display Symbols: Systolic pressure, Diastolic pressure, Pulse rate, Battery indicator, Memory full, Arrhythmia symbol, WHO classification bar, Date/Time, User indicator (for multiple users).
Before first use: Install batteries or connect AC adapter. Set date and time. Apply cuff properly.
Tip: Rest for 5 minutes before first measurement. Sit comfortably with feet flat on floor.
For accurate results: Avoid eating, smoking, or caffeine 30 minutes before measurement.
WARNING! Do not inflate cuff more than once within 2 minutes to avoid injury.
Memory stores 99 readings with date and time. Supports tracking for multiple users (on some models).
Note: Memory is preserved when batteries are removed for up to 5 minutes.
Clean device with soft, dry cloth only. Do not use chemicals or immerse in water.
CAUTION! Do not disassemble device. No user-serviceable parts inside.
This device complies with Part 15 of the FCC Rules. Operation is subject to the condition that it does not cause harmful interference. Medical device classification: Class IIa according to MDD 93/42/EEC. CE marked. Manufactured under ISO 13485 quality standards. For support, visit www.microlife.com or contact your local Microlife service center.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Dead batteries | Replace all 4 batteries with fresh ones. |
| Error code E1 | Cuff not properly attached | Check cuff connection; ensure tube is not kinked. |
| Error code E2 | Measurement error | Move less during measurement; ensure cuff at heart level. |
| Error code E3 | Pressure too high | Consult physician; do not attempt multiple measurements. |
| Inconsistent readings | Wrong cuff position | Reapply cuff correctly; rest 5 minutes between readings. |
| Device turns off during measurement | Low battery | Replace batteries or use AC adapter. |
| Memory not working | Memory full | Delete old readings or reset memory. |
| Arrhythmia symbol flashes | Irregular heartbeat detected | Consult physician; take multiple readings for confirmation. |
Reset: Remove batteries for 5 minutes to reset device to factory settings.
Service: Contact authorized Microlife service center. Do not attempt repairs yourself.