The Microlife Aponorm Professional Control is a clinically validated, automatic upper arm blood pressure monitor designed for professional and home use. It features advanced Microlife Average Mode (MAM) technology for reliable average readings, irregular heartbeat detection, hypertension indicator, large memory storage, adjustable cuff, clear display with backlight, and data transfer capabilities. Below are key sections for safety, features, setup, measurement, maintenance, and troubleshooting.
Key components: Main unit with LCD display, Adjustable upper arm cuff, Air tube, AC adapter port, USB port for data, START/STOP button, MEMORY button, MAM button.
| Feature | Description |
|---|---|
| Microlife Average Mode (MAM) | Takes three consecutive readings and displays the average |
| Irregular Heartbeat Detection (IHD) | Detects pulse irregularities during measurement |
| Hypertension Indicator | Color-coded bar graph based on WHO classification |
| Large Memory | Stores up to 99 readings for two users (198 total) |
| Adjustable Cuff | Fits arm circumferences 22-42 cm |
| Clear LCD Display | Shows systolic, diastolic, pulse, date & time |
| Data Transfer | USB connection for PC software (optional) |
| Automatic Power Off | Conserves battery life |
| Backlight | For easy reading in low light |
| Clinically Validated | Meets international protocols for accuracy |
Read all instructions before use.
WARNING! This device is not a substitute for professional medical diagnosis. Consult your doctor for interpretation of results and treatment.
CAUTION! Inspect contents upon unpacking. Do not use if any part appears damaged.
Front Panel: LCD Display, START/STOP Button, MEMORY Button, MAM Button, USER Button (1/2).
Side/Back: AC Adapter Socket, USB Port (for data), Cuff Socket, Battery Compartment.
Display Symbols: Systolic Pressure, Diastolic Pressure, Pulse Rate, Irregular Heartbeat Symbol, Hypertension Indicator Bar, User Icon, Memory Icon, Battery Icon, Date/Time, MAM Icon.
Power on the device and configure basic settings.
Tip: For most accurate results, rest for 5 minutes before first measurement.
Follow these steps for a proper reading.
WARNING! Do not inflate cuff when not wrapped around arm.
The display shows systolic (high number) and diastolic (low number) pressure in mmHg, and pulse rate in BPM.
Hypertension Indicator (Bar Graph): - Green: Optimal/Normal (<130/85 mmHg) - Yellow: High Normal (130-139/85-89 mmHg) - Orange: Grade 1 Hypertension (140-159/90-99 mmHg) - Red: Grade 2 or 3 Hypertension (>=160/100 mmHg)
Irregular Heartbeat Symbol: Appears if an irregular rhythm is detected during measurement. Consult your doctor if it appears frequently.
Stores 99 readings per user.
Unplug cuff and remove batteries before cleaning.
CAUTION! Do not use alcohol, solvents, or abrasive cleaners. Do not attempt to repair device yourself.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Dead batteries | Replace all 4 AA batteries. |
| Error Code "E" | Cuff not connected or leak | Ensure cuff tube is plugged in tightly. Check cuff for holes. |
| Error Code "E1" | Measurement error | Reposition cuff correctly at heart level. Remain still and retry. |
| Irregular Heartbeat symbol flashes | Irregular pulse detected | Result may be less accurate. Retake measurement. Consult doctor if frequent. |
| Reading seems too high/low | Incorrect posture or cuff position | Ensure proper sitting posture and cuff position at heart level. Rest 5 min before measuring. |
| Memory full | 99 readings stored for user | Delete old readings or switch to other user profile. |
Reset: Remove batteries for 5 minutes to reset device.
Service: For technical support, contact Microlife Customer Service or visit www.microlife.com. Do not open the device.