The Microlife BP 3BM1-3P is an automatic upper arm blood pressure monitor designed for home use. It features one-touch operation, a large LCD display with backlight, irregular heartbeat detection, 2-user memory with 60 measurements each, WHO blood pressure classification indicator, date and time display, and an adjustable cuff for arm circumferences 22-42 cm. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.
Key components: Main unit with LCD display, Adjustable arm cuff, Air tube, 4x AA batteries, Instruction manual, Storage case.
| Feature | Description |
|---|---|
| One-Touch Operation | Fully automatic inflation and measurement |
| Large LCD Display | Clear backlit display for easy reading |
| 2-User Memory | Stores 60 measurements per user |
| WHO Classification Indicator | Color-coded display of blood pressure category |
| Irregular Heartbeat Detection | Detects and displays irregular heartbeat during measurement |
| Adjustable Cuff | Fits arm circumferences 22-42 cm (9-16.5 inches) |
| Date & Time Stamp | Records measurement date and time |
| Automatic Power Off | Conserves battery life |
| Average Value | Calculates average of last 3 measurements per user |
| Error Detection | Alerts for incorrect cuff placement or movement |
Read all instructions before use. For personal home use only.
WARNING! This device is not a substitute for professional medical diagnosis. Always consult your physician about your blood pressure.
CAUTION! Check all items are present and undamaged before use.
Front Panel: START/STOP button, USER 1/USER 2 buttons, MEMORY button, LCD display.
Display Symbols: Systolic pressure, Diastolic pressure, Pulse rate, User indicator, Memory full, Battery low, Irregular heartbeat symbol, WHO color bar, Date/Time, Error codes.
Connections: Air tube socket (rear), Cuff connector.
First-time preparation steps:
Tip: Rest for 5 minutes before first measurement. Avoid talking or moving during measurement.
Follow these steps for accurate readings:
WARNING! Do not over-tighten cuff. Stop measurement if pain or discomfort occurs.
Device stores 60 measurements for each of 2 users.
Note: Date and time stored with each measurement.
WHO Classification: Color bar on display indicates: Green (Optimal/Normal), Yellow (High Normal/Mild Hypertension), Red (Moderate/Severe Hypertension).
Irregular Heartbeat Detection: Symbol appears if irregular rhythm detected during measurement. Consult physician if symbol appears frequently.
Unplug air tube and remove batteries before cleaning.
CAUTION! Do not immerse in water. Avoid chemicals, direct sunlight, strong impacts.
Replace when low battery symbol appears.
Warning: Use only recommended battery type. Remove batteries if not using for extended period.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Dead batteries | Replace all 4 batteries with new ones. |
| Error code E1 | Cuff not properly attached | Reconnect cuff tube securely to device. |
| Error code E2 | Measurement error | Ensure cuff positioned correctly; remain still; retry. |
| Error code E3 | Irregular heartbeat detected | Measurement may be inaccurate; retry; consult doctor if frequent. |
| Inaccurate reading | Wrong position/movement | Sit correctly with arm at heart level; avoid movement/talking. |
| Cuff does not inflate | Tube blockage/leak | Check tube connections; ensure cuff not twisted or damaged. |
| Memory not working | Battery low | Replace batteries; data may be lost if batteries completely dead. |
Reset: Remove batteries for 5 minutes, then reinsert.
Service: For technical support, contact Microlife Customer Service at 1-800-566-3456 or visit www.microlife.com.