The Microlife BP 3BTO-A(2) is an automatic upper arm blood pressure monitor with clinically validated accuracy, featuring one-touch operation, irregular heartbeat detection, 2-user memory with 99 readings each, date and time display, WHO blood pressure classification indicator, and an easy-to-read LCD display. It includes a standard cuff (22-32 cm) and operates on 4 AA batteries or via optional AC adapter. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.
Key components: Main unit with LCD display, Arm cuff with D-ring, Air tube, 4 AA batteries, Instruction manual, Storage case.
| Feature | Description |
|---|---|
| One-Touch Operation | Fully automatic inflation and deflation |
| WHO Indicator | Color-coded display shows blood pressure classification |
| Irregular Heartbeat Detection | Detects pulse irregularities during measurement |
| 2-User Memory | Stores 99 readings for each of two users |
| Date & Time Stamp | Records measurement date and time |
| Average Value | Calculates average of last 3 readings per user |
| Large LCD Display | Easy-to-read digits and icons |
| Automatic Power Off | Conserves battery life |
| Cuff Fit Indicator | Ensures proper cuff placement |
| Battery/AC Operation | 4 AA batteries or optional AC adapter |
Read all instructions before use. For personal home use only.
WARNING! Not for medical diagnosis. Consult healthcare professional for interpretation of readings.
Note: Check all items upon unpacking. Contact retailer if anything is missing or damaged.
Front Panel: START/STOP button, USER 1/USER 2 buttons, MEMORY button, LCD display.
Display Symbols: Systolic/Diastolic pressure, Pulse rate, User indicator, Memory full, Battery low, Irregular heartbeat, Cuff error, WHO classification bar.
Side/Back: Air tube connector, AC adapter jack (optional), Battery compartment.
Cuff: Velcro closure, D-ring, artery marker, air tube connector.
Prepare device for first use.
CAUTION! Use only recommended batteries. Remove batteries if not used for extended periods.
For accurate results, follow these steps carefully.
Tip: Take measurements at same time each day for consistent tracking.
The WHO classification bar appears after each measurement.
| Color Zone | Blood Pressure Category | Systolic/Diastolic Range |
|---|---|---|
| Green | Normal | Below 130 / Below 85 |
| Yellow | High-Normal | 130-139 / 85-89 |
| Orange | Mild Hypertension | 140-159 / 90-99 |
| Red | Moderate/Severe Hypertension | 160+ / 100+ |
Irregular Heartbeat Symbol: Appears if irregular pulse is detected during measurement. Consult physician if it appears frequently.
Stores 99 readings per user with date and time.
Note: Memory full icon appears when 99 readings are stored. Oldest reading is overwritten.
Unplug air tube and remove batteries before cleaning.
CAUTION! Do not use alcohol, benzene, or abrasive cleaners. Do not disassemble device.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Dead batteries | Replace all 4 batteries with new ones. |
| Error E1 | Cuff not attached properly | Check air tube connection; ensure cuff is not twisted. |
| Error E2 | Cuff pressure error | Do not move during measurement; ensure cuff fits properly. |
| Error E3 | Pulse signal too weak | Reposition cuff; remain still; avoid talking. |
| Inconsistent readings | Incorrect posture or timing | Rest 5 minutes before measuring; keep arm at heart level. |
| Cuff does not inflate | Air leak or blockage | Check tube for kinks; ensure connector is secure. |
| Memory not working | Batteries very low | Replace batteries; data may be lost if batteries dead. |
Reset: Remove batteries for 5 minutes to reset device.
Service: For technical support, contact Microlife Customer Service at 1-800-xxx-xxxx or visit www.microlife.com