The Microlife BP 3BTO-A(2) is an automatic upper arm blood pressure monitor with clinically validated accuracy, featuring one-touch operation, irregular heartbeat detection, 2-user memory with 99 readings each, date and time display, WHO blood pressure classification indicator, and an easy-to-read LCD display. It includes a standard cuff (22-32 cm) and operates on 4 AA batteries or via optional AC adapter. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Safety Information 3. Package Contents 4. Device Overview 5. Initial Setup 6. Taking a Measurement 7. Understanding Results 8. Memory Function 9. Care & Maintenance 10. Technical Specifications 11. Troubleshooting

Features at a Glance

Key components: Main unit with LCD display, Arm cuff with D-ring, Air tube, 4 AA batteries, Instruction manual, Storage case.

FeatureDescription
One-Touch OperationFully automatic inflation and deflation
WHO IndicatorColor-coded display shows blood pressure classification
Irregular Heartbeat DetectionDetects pulse irregularities during measurement
2-User MemoryStores 99 readings for each of two users
Date & Time StampRecords measurement date and time
Average ValueCalculates average of last 3 readings per user
Large LCD DisplayEasy-to-read digits and icons
Automatic Power OffConserves battery life
Cuff Fit IndicatorEnsures proper cuff placement
Battery/AC Operation4 AA batteries or optional AC adapter

Safety Information

Read all instructions before use. For personal home use only.

  1. Do not use on infants, small children, or persons unable to express themselves.
  2. Consult physician before use if you have arrhythmia, atherosclerosis, or other circulatory disorders.
  3. Do not use during blood dialysis or if you have pre-eclampsia.
  4. Measure at consistent times daily, before medication and meals.
  5. Avoid caffeine, smoking, and exercise 30 minutes before measurement.

WARNING! Not for medical diagnosis. Consult healthcare professional for interpretation of readings.

Package Contents

Note: Check all items upon unpacking. Contact retailer if anything is missing or damaged.

Device Overview

Front Panel: START/STOP button, USER 1/USER 2 buttons, MEMORY button, LCD display.

Display Symbols: Systolic/Diastolic pressure, Pulse rate, User indicator, Memory full, Battery low, Irregular heartbeat, Cuff error, WHO classification bar.

Side/Back: Air tube connector, AC adapter jack (optional), Battery compartment.

Cuff: Velcro closure, D-ring, artery marker, air tube connector.

Initial Setup

Prepare device for first use.

  1. Insert batteries: Open battery compartment, insert 4 AA batteries observing polarity.
  2. Set date and time: Press and hold MEMORY button for 3 seconds, use START/STOP to adjust.
  3. Connect cuff: Insert air tube connector into monitor socket until it clicks.
  4. Select user: Press USER 1 or USER 2 button to choose user profile.

CAUTION! Use only recommended batteries. Remove batteries if not used for extended periods.

Taking a Measurement

For accurate results, follow these steps carefully.

  1. Sit comfortably: Rest for 5 minutes with feet flat on floor.
  2. Apply cuff: Place cuff on bare upper arm 1-2 cm above elbow. Artery marker should align with brachial artery.
  3. Position arm: Keep cuff at heart level. Rest arm on table.
  4. Start measurement: Press START/STOP button. Cuff inflates automatically.
  5. Remain still: Do not talk or move during measurement.
  6. Read results: Display shows systolic, diastolic, and pulse rate.
  7. Cuff deflates: Automatically after reading is complete.

Tip: Take measurements at same time each day for consistent tracking.

Understanding Results

The WHO classification bar appears after each measurement.

Color ZoneBlood Pressure CategorySystolic/Diastolic Range
GreenNormalBelow 130 / Below 85
YellowHigh-Normal130-139 / 85-89
OrangeMild Hypertension140-159 / 90-99
RedModerate/Severe Hypertension160+ / 100+

Irregular Heartbeat Symbol: Appears if irregular pulse is detected during measurement. Consult physician if it appears frequently.

Memory Function

Stores 99 readings per user with date and time.

  1. View memory: Press MEMORY button to scroll through stored readings.
  2. Average reading: After 3+ readings, display shows average of last 3 measurements.
  3. Clear memory: Press and hold USER button for 5 seconds while in memory mode.
  4. Switch users: Press USER 1 or USER 2 to access different memory sets.

Note: Memory full icon appears when 99 readings are stored. Oldest reading is overwritten.

Care & Maintenance

Unplug air tube and remove batteries before cleaning.

  1. Clean monitor: Use slightly damp cloth. Do not immerse in water.
  2. Clean cuff: Wipe with mild soap solution. Do not machine wash.
  3. Storage: Keep in case provided, away from extreme temperatures and humidity.
  4. Batteries: Replace when low battery icon appears. Use alkaline batteries.

CAUTION! Do not use alcohol, benzene, or abrasive cleaners. Do not disassemble device.

Technical Specifications

Troubleshooting

SymptomPossible CauseCorrective Action
No displayDead batteriesReplace all 4 batteries with new ones.
Error E1Cuff not attached properlyCheck air tube connection; ensure cuff is not twisted.
Error E2Cuff pressure errorDo not move during measurement; ensure cuff fits properly.
Error E3Pulse signal too weakReposition cuff; remain still; avoid talking.
Inconsistent readingsIncorrect posture or timingRest 5 minutes before measuring; keep arm at heart level.
Cuff does not inflateAir leak or blockageCheck tube for kinks; ensure connector is secure.
Memory not workingBatteries very lowReplace batteries; data may be lost if batteries dead.

Reset: Remove batteries for 5 minutes to reset device.

Service: For technical support, contact Microlife Customer Service at 1-800-xxx-xxxx or visit www.microlife.com

Microlife BP 3BTO-A(2) Blood Pressure Monitor User Manual © - All Rights Reserved 2025