The Microlife BP 3BTO-AP is an automatic upper arm blood pressure monitor with advanced accuracy, irregular heartbeat detection, and a large memory function. It features a clinically validated measurement technology, a clear LCD display with backlight, adjustable cuff, one-touch operation, and is designed for easy home use. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.
Key components: Main unit with LCD display, Adjustable arm cuff, Air tube, Storage case, Instruction manual, Batteries.
| Feature | Description |
|---|---|
| Automatic Inflation & Deflation | One-touch operation for easy measurement |
| Clinically Validated Accuracy | Meets international protocols for reliability |
| Irregular Heartbeat Detection | Detects pulse irregularities during measurement |
| Large Memory Capacity | Stores up to 99 readings for two users |
| XL Cuff Included | Fits arm circumferences 22-42 cm |
| Clear LCD Display with Backlight | Easy-to-read results in various lighting |
| WHO Classification Indicator | Color-coded bar graph for quick assessment |
| Date & Time Stamp | Records measurement time for tracking |
| Automatic Power Off | Conserves battery life |
| Battery & AC Adapter Option | Powered by 4 AA batteries or optional adapter |
Read all instructions before use. For personal home use only.
WARNING! This device is not a substitute for professional medical advice. Seek immediate medical attention for abnormal readings or symptoms.
CAUTION! Check contents upon unboxing. Do not use if any part is damaged.
Front Panel: START/STOP button, MEMORY button, USER button (1/2), Display screen.
Display Symbols: Systolic pressure, Diastolic pressure, Pulse rate, Irregular heartbeat symbol, User indicator, Memory index, Battery indicator, WHO classification bar, Date/Time.
Connections: Cuff socket (left side), DC input (for optional adapter, bottom).
Prepare the device for initial measurement.
Tip: Avoid eating, smoking, or caffeine 30 minutes before measurement.
Follow these steps for accurate readings.
WARNING! Do not inflate cuff without proper arm placement to avoid injury.
Refer to WHO classification on display.
| Category | Systolic (mmHg) | Diastolic (mmHg) | Display Bar Color |
|---|---|---|---|
| Low | < 90 | < 60 | Blue |
| Ideal | 90-119 | 60-79 | Green |
| Pre-Hypertension | 120-139 | 80-89 | Yellow |
| Hypertension Stage 1 | 140-159 | 90-99 | Orange |
| Hypertension Stage 2 | 160-179 | 100-109 | Red |
| Severe Hypertension | ≥ 180 | ≥ 110 | Flashing Red |
Irregular Heartbeat Symbol: Appears if irregular pulse is detected. Consult physician if frequent.
Stores 99 readings per user (2 users total).
Note: Memory is retained when batteries are replaced if done within 2 minutes.
CAUTION! Remove batteries if device will not be used for extended periods. Do not mix old and new batteries.
Remove batteries before cleaning.
WARNING! Do not attempt to repair or disassemble the device. Contact authorized service.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Dead batteries | Replace all 4 batteries with new ones. |
| Error Code E1 | Cuff not attached/leaking | Check cuff connection; ensure cuff is properly applied. |
| Error Code E2 | Measurement error | Remain still; repeat measurement. Check cuff position. |
| Error Code E3 | Pulse too irregular/weak | Rest and try again. Consult physician if persistent. |
| Inaccurate reading | Incorrect posture/cuff | Follow measurement procedure exactly. Ensure correct cuff size. |
| Memory not working | Batteries removed too long | Memory is cleared if batteries are out >2 minutes. |
Reset: Remove batteries, wait 2 minutes, reinsert.
Service: For technical support, contact Microlife Customer Service at 1-800-xxx-xxxx or visit www.microlife.com.