The Microlife BP 3BU1-4 is an automatic upper arm blood pressure monitor designed for home use. It features a large, easy-to-read LCD display, one-touch operation, irregular heartbeat detection, 2-user memory with 99 measurements each, WHO blood pressure classification indicator, and an adjustable cuff for arm circumferences 22-42 cm. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.
Key components: Main unit, adjustable arm cuff, instruction manual, storage case, and batteries.
| Feature | Description |
|---|---|
| One-Touch Operation | Automatic inflation and measurement |
| WHO Classification Indicator | Color-coded display of blood pressure levels |
| 2 x 99 Memory | Stores readings for two users separately |
| Irregular Heartbeat Detection (IHD) | Detects and indicates irregular heartbeats during measurement |
| Large LCD Display | Easy-to-read results with date and time |
| Adjustable Cuff | Fits arm circumferences 22-42 cm (9-16.5 inches) |
| Automatic Power Off | Conserves battery life |
| Average of Last 3 Readings | Calculates and displays average for each user |
| Date & Time Stamp | Records measurement date and time |
| Error Detection | Alerts for incorrect cuff placement or movement |
Unpack and verify all items are present.
WARNING! Do not use if any components are damaged. Contact customer support.
Front Panel: START/STOP button, MEMORY button, USER 1/USER 2 selection button, LCD display.
Display Symbols: Systolic pressure, Diastolic pressure, Pulse rate, User indicator, Battery low, Irregular heartbeat symbol, WHO classification bar, Date/Time, Memory recall number.
Cuff: Marked with artery index line for proper positioning.
Prepare the device for initial measurement.
CAUTION! Ensure cuff is snug but not too tight. Rest for 5 minutes before measuring.
For accurate results, follow these steps carefully.
Tip: Take measurements at same time each day for consistent tracking.
View and manage stored measurements.
Note: Memory is preserved when batteries are removed.
WHO classification bar on display indicates blood pressure category.
| Color Zone | Category | Systolic (mmHg) | Diastolic (mmHg) |
|---|---|---|---|
| Green | Optimal | < 120 | < 80 |
| Yellow | Normal | 120-129 | 80-84 |
| Orange | High Normal | 130-139 | 85-89 |
| Red | Hypertension | ≥ 140 | ≥ 90 |
Irregular Heartbeat Symbol: If displayed, measurement may be affected by arrhythmia. Repeat measurement.
Important: This device is for home monitoring only. Consult healthcare professional for diagnosis.
Remove batteries before cleaning. Use slightly damp cloth with mild detergent. Do not immerse in water.
CAUTION! Do not use alcohol, benzene, or abrasive cleaners. Store in case when not in use.
Battery life: Approximately 500 measurements (alkaline batteries).
WARNING! Do not mix old and new batteries. Dispose of batteries properly.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Dead batteries | Replace all 4 batteries with new ones. |
| Error Code E1 | Cuff not properly attached | Check cuff connection to device. |
| Error Code E2 | Measurement error | Ensure cuff is at heart level; remain still; repeat measurement. |
| Error Code E3 | Irregular heartbeat detected | Wait 5 minutes and measure again. If persistent, consult doctor. |
| Inaccurate reading | Wrong cuff position | Align artery marker with brachial artery; cuff should be snug. |
| Memory not working | Wrong user selected | Press USER button to select correct user profile. |
| Device turns off during use | Low batteries | Replace batteries immediately. |
Reset: Remove batteries for 1 minute to reset device.
Service: For technical support, contact Microlife customer service or visit www.microlife.com