The Microlife BP 3SK1-3B is an automatic upper arm blood pressure monitor with clinically validated accuracy, one-touch operation, irregular heartbeat detection, 2-user memory with 99 measurements each, WHO blood pressure classification indicator, large LCD display with backlight, adjustable cuff (22-42 cm), and automatic power-off. Below are key sections for safety, features, setup, measurement, memory, and troubleshooting.
Key components: Main unit with LCD display, Adjustable arm cuff, AC adapter port, Battery compartment, START/STOP button, MEMORY button.
| Feature | Description |
|---|---|
| One-Touch Operation | Automatic inflation and measurement with single button press |
| Irregular Heartbeat Detection | Detects and displays irregular heartbeats during measurement |
| 2-User Memory | Stores 99 measurements for each of two users |
| WHO Classification Indicator | Shows color-coded blood pressure classification |
| Large LCD Display | Easy-to-read results with backlight for low light |
| Adjustable Cuff | Fits arm circumferences 22-42 cm (8.7-16.5 inches) |
| Automatic Power Off | Conserves battery life by turning off after 1 minute |
| Date & Time Stamp | Records measurement date and time in memory |
| Average Value | Calculates average of last 3 measurements per user |
| Battery/AC Operation | 4xAA batteries or optional AC adapter |
Read all instructions before use. For accurate measurements and safety:
WARNING! This device is for home use only, not for professional medical diagnosis. Always follow your doctor's instructions regarding blood pressure measurement.
Note: Batteries may not be included. Requires 4xAA alkaline batteries.
Front Panel: LCD display, START/STOP button, MEMORY button, USER 1/2 selector.
Display Symbols: Systolic pressure, Diastolic pressure, Pulse rate, Irregular heartbeat indicator, WHO classification bar, User indicator, Memory full, Battery low, Date/Time.
Side/Back: Cuff connector port, AC adapter port, Battery compartment.
Cuff: Marked with artery index line, Velcro closure, metal D-ring, air tube connector.
Before first use:
CAUTION! Use only recommended batteries. Do not mix old and new batteries.
For accurate results:
Tip: Take measurements at same time each day for consistent tracking.
2-user memory with 99 measurements each:
Note: When memory is full, oldest reading is automatically deleted for new one.
Color-coded blood pressure classification based on WHO guidelines:
| Color Zone | Blood Pressure Category | Systolic/Diastolic |
|---|---|---|
| Green | Optimal | < 120 / < 80 mmHg |
| Yellow | Normal | 120-129 / 80-84 mmHg |
| Orange | High Normal | 130-139 / 85-89 mmHg |
| Red | Hypertension | ≥ 140 / ≥ 90 mmHg |
The indicator bar lights up to show which category your reading falls into.
Unplug/battery removal before cleaning. Use slightly damp cloth; do not immerse in water.
CAUTION! Do not disassemble device. No user-serviceable parts inside.
| Display Symbol | Meaning | Action |
|---|---|---|
| E1 | Cuff not properly attached or leaking | Check cuff connection; ensure proper wrapping |
| E2 | Measurement error | Remain still; retake measurement |
| E3 | Pulse rate outside range (40-200 bpm) | Rest and measure again |
| E4 | Excessive movement during measurement | Keep arm still; retake |
| E5 | Pressure exceeds 300 mmHg | Consult physician |
| Battery Icon | Low battery | Replace all 4 batteries |
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Dead batteries | Replace all 4 batteries with new alkaline batteries |
| Inaccurate reading | Wrong cuff position | Ensure cuff at heart level; artery line aligned |
| Cuff doesn't inflate | Tube not connected | Check cuff connection to device |
| Error messages | Movement or irregular heartbeat | Keep still; if persistent, consult physician |
| Memory not storing | Memory full or user not selected | Clear memory or select user before measuring |
Reset: Remove batteries for 1 minute to reset device.
Service: For technical support, contact Microlife customer service or visit www.microlife.com