The Microlife BP A150-30 AFIB is an automatic upper arm blood pressure monitor with patented AFIB (Atrial Fibrillation) detection technology, clinically validated for accuracy. It features a large, easy-to-read LCD display, one-touch operation, memory storage for multiple users, irregular heartbeat detection, WHO blood pressure classification indicator, and comfortable D-ring cuff. Below are key sections for safety, features, setup, measurement, maintenance, and troubleshooting.
Key components: Main unit with LCD display, D-ring cuff, AC adapter, storage case, and instruction manual.
| Feature | Description |
|---|---|
| AFIB Detection | Patented technology to screen for atrial fibrillation during measurement |
| One-Touch Operation | Automatic inflation and deflation for easy use |
| Dual User Memory | Stores up to 99 readings per user with date and time stamp |
| WHO Indicator | Color-coded bar graph showing blood pressure classification |
| Irregular Heartbeat Detection | Detects and displays irregular heartbeat occurrences |
| Large LCD Display | Clear, backlit display with large digits for easy reading |
| Comfortable Cuff | 22-42 cm D-ring cuff for secure self-application |
| Automatic Power Off | Conserves battery life by turning off after 1 minute of inactivity |
| AVG Function | Calculates average of last 3 readings taken within 10 minutes |
| Date/Time Display | Built-in clock for accurate reading time stamps |
Read all instructions before use. Keep for future reference.
WARNING! Do not use on injured or sore arms. If you feel unwell during measurement, stop immediately.
Unpack and verify all components are present.
CAUTION! Do not use if package is damaged or components are missing.
Front Panel: LCD display, START/STOP button, MEMORY button, USER button. Cuff: Air tube connector, D-ring closure, artery marker.
Display Symbols: Systolic/Diastolic pressure, Pulse rate, AFIB symbol, Irregular heartbeat symbol, User indicator (1/2), Memory full indicator, Battery indicator, WHO color bar, Date/Time, AVG symbol.
Connections: Cuff connector port, DC power input. Battery compartment: Requires 4 x AA batteries (optional, not included).
Prepare device for first use.
Tip: For most accurate results, use AC adapter instead of batteries.
For accurate readings, follow proper procedure.
WARNING! Do not inflate cuff when not wrapped around arm.
Interpretation of displayed information.
| Display | Meaning | Normal Range |
|---|---|---|
| Systolic | Maximum pressure during heartbeat | 90-120 mmHg |
| Diastolic | Minimum pressure between heartbeats | 60-80 mmHg |
| Pulse | Heart rate per minute | 60-100 bpm |
| AFIB Symbol | Possible atrial fibrillation detected | Consult physician |
| Irregular Heartbeat | Occasional irregular heartbeat detected | Note frequency |
| WHO Bar | Color indicates category (Green=Normal, Yellow=Elevated, Red=High) | Green zone ideal |
Note: AFIB detection is a screening tool, not a diagnosis. Consult healthcare provider for abnormal results.
Managing stored readings.
Tip: Record readings in a log book for doctor visits.
Proper care ensures accuracy and longevity.
CAUTION! Never immerse device in water or other liquids.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Dead batteries | Replace batteries or connect AC adapter |
| Error E1 | Cuff not connected properly | Check cuff connection, restart measurement |
| Error E2 | Cuff pressure too high | Remove cuff, restart, ensure proper application |
| Error E3 | Measurement error | Remain still, ensure cuff at heart level, retry |
| Error E4 | Pulse signal too weak | Reposition cuff, ensure snug fit, retry |
| Inconsistent readings | Improper posture/cuff position | Follow measurement procedure exactly |
| Memory not saving | Memory full | Delete old readings or switch to other user |
| AFIB symbol always on | Possible persistent arrhythmia | Consult healthcare professional |
Reset: Remove batteries for 1 minute to reset device.
Service: Contact Microlife customer service at 1-800-566-0456 or visit www.microlife.com