The Microlife BP A2 Easy is a fully automatic upper-arm blood pressure monitor designed for easy, accurate home use. It features one-touch operation, a large LCD display with backlight, irregular heartbeat detection, 2-user memory with 99 readings each, date and time display, automatic averaging of the last 3 readings, and WHO blood pressure classification indicator. Powered by 4xAA batteries or AC adapter (optional). Below are key sections for safety, features, setup, measurement, memory, maintenance, and troubleshooting.
Key components: Main unit with LCD display, Upper-arm cuff with D-Ring, AC adapter port (optional), Battery compartment.
| Feature | Description |
|---|---|
| One-Touch Operation | Fully automatic inflation and measurement |
| Large LCD Display | Clear readout with backlight for low light |
| WHO Indicator | Color-coded bar graph showing blood pressure classification |
| Irregular Heartbeat Detection (IHD) | Detects pulse irregularities during measurement |
| 2x99 Memory | Stores 99 readings for each of two users |
| 3-in-1 Display | Shows systolic, diastolic pressure and pulse rate simultaneously |
| Automatic Averaging | Calculates average of last 3 readings taken within 10 minutes |
| Date & Time Stamp | Records measurement date and time for tracking |
| Automatic Power Off | Conserves battery life |
| Cuff Fit Indicator | Verifies proper cuff placement |
Read all instructions before use.
WARNING! Do not use while connected to other electronic medical devices (e.g., pacemakers). Ensure cuff is not too tight. Rest for 5 minutes before measuring.
CAUTION! Inspect contents upon unpacking. Do not use if any part is damaged.
Front Panel: START/STOP button, MEMORY button, User selector (1/2), LCD display.
Display Symbols: Systolic pressure, Diastolic pressure, Pulse rate, User indicator (1 or 2), Battery icon, WHO bar graph, Irregular heartbeat symbol (heart with *), Date/Time, Memory full icon, Cuff error icon.
Side/Back: Cuff connector port, AC adapter port (DC 6V), Battery compartment cover.
Power on and configure device.
Tip: For first-time use, practice applying the cuff without turning the device on.
For accurate results, follow these steps carefully.
WARNING! Do not move or talk during measurement. Do not inflate cuff without it being properly applied.
Stores 99 readings per user with date and time.
Note: Memory is retained when batteries are removed.
Refer to the WHO classification bar on the display.
| WHO Color Zone | Systolic (mmHg) | Diastolic (mmHg) | Category |
|---|---|---|---|
| Blue | Below 120 | and Below 80 | Optimal |
| Green | 120-129 | and/or 80-84 | Normal |
| Yellow | 130-139 | and/or 85-89 | High-Normal |
| Orange | 140-159 | and/or 90-99 | Grade 1 Hypertension |
| Red | 160 or higher | and/or 100 or higher | Grade 2/3 Hypertension |
Irregular Heartbeat Symbol: If this icon flashes during or after measurement, it may indicate an irregular pulse rhythm. Consult your physician if it appears frequently.
Unplug AC adapter (if used) and remove batteries before cleaning.
CAUTION! The cuff contains a sensitive air bladder. Avoid sharp bends, kinks, or excessive force on the tube.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Display is blank | Batteries dead/incorrect | Replace with new batteries; ensure correct polarity. |
| Error Code "E" flashes | Cuff not connected/leaking | Ensure cuff tube is firmly connected. Check cuff for holes or tears. |
| Error Code "Err" | Measurement error | Reapply cuff correctly at heart level. Remain still and retake measurement. |
| Inaccurate reading | Improper posture/cuff position | Sit correctly with cuff at heart level. Ensure cuff fits snugly (1 finger fit under cuff). |
| Device does not inflate | Blocked air tube/batteries weak | Check tube for kinks. Replace batteries. |
| Memory full icon | 99 readings stored for selected user | Review and clear memory if desired. |
Reset: Remove batteries for 1 minute to reset the microprocessor.
Service: Do not attempt to repair. Contact Microlife customer service or an authorized service center. For support, visit www.microlife.com or contact your local distributor.