Microlife BP AG1-20 Blood Pressure Monitor User Manual

The Microlife BP AG1-20 is an automatic upper arm blood pressure monitor with clinically validated accuracy, one-touch operation, large LCD display, irregular heartbeat detection, hypertension indicator, memory storage for multiple users, adjustable cuff, and WHO classification indicator. Powered by 4 AA batteries or AC adapter. Below are key sections for safety, features, setup, measurement, maintenance, and troubleshooting.

1. Features at a Glance 2. Safety Information 3. First-Time Setup 4. Specifications 5. Controls and Display 6. Taking Measurements 7. Memory Function 8. Care & Maintenance 9. Regulatory Information 10. Troubleshooting

Features at a Glance

Key components: Main unit with LCD display, Adjustable arm cuff, AC adapter port, Battery compartment, START/STOP button, Memory recall button.

FeatureDescription
One-Touch OperationAutomatic inflation and measurement
Irregular Heartbeat DetectionDetects pulse irregularities during measurement
WHO Classification IndicatorShows blood pressure classification
Hypertension IndicatorAlerts when readings are high
Memory FunctionStores readings for multiple users
Adjustable CuffFits arm circumference 22-32 cm
Large LCD DisplayEasy-to-read results
Automatic Power OffConserves battery life
Date/Time StampRecords measurement time
Battery/AC Operation4 AA batteries or AC adapter

Safety Information

Read all instructions before use. Keep away from children.

  1. Do not use on infants or persons unable to express themselves.
  2. Do not use during dialysis or with intravenous infusion in measurement arm.
  3. Consult physician before use if you have arrhythmia, pre-eclampsia, or other circulatory disorders.
  4. Do not use in high humidity or near flammable gases.

WARNING! This device is not a substitute for professional medical diagnosis. Always consult your physician about blood pressure readings.

First-Time Setup

Prepare device for first use.

  1. Insert batteries: Open battery compartment, insert 4 AA batteries observing polarity.
  2. Set date/time: Press and hold MEMORY button for 3 seconds, use START to adjust.
  3. Apply cuff: Wrap cuff on bare upper arm 1-2 cm above elbow.
  4. Position: Sit comfortably with feet flat, back supported, arm at heart level.

CAUTION! Ensure cuff is not twisted and fits snugly but not too tight.

Specifications

Controls and Display

Front Panel: START/STOP button, MEMORY button, LCD display.

Display Symbols: Systolic pressure, Diastolic pressure, Pulse rate, User indicator (1/2), Memory full, Battery low, Irregular heartbeat, WHO classification, Date/Time.

Settings: Date/Time setup, User selection, Memory recall, Unit selection (mmHg/kPa).

Taking Measurements

For accurate readings, follow these steps:

  1. Rest for 5 minutes before measuring.
  2. Sit in chair with back supported.
  3. Apply cuff to left arm (unless instructed otherwise).
  4. Position arm so cuff is at heart level.
  5. Press START button - device inflates automatically.
  6. Remain still and quiet during measurement.
  7. Read results on display when measurement completes.
  8. Press START to turn off or wait for auto power-off.

Tip: Take measurements at same time each day for consistent tracking.

Memory Function

Stores 60 readings per user for 2 users.

  1. Select user: Press MEMORY briefly to toggle between User 1 and User 2.
  2. Recall memory: Press and hold MEMORY for 2 seconds to view stored readings.
  3. Navigate: Use START button to scroll through stored readings.
  4. Clear memory: In memory mode, press and hold both buttons for 5 seconds.

Note: Memory full indicator appears when storage capacity is reached.

Care & Maintenance

Clean with soft, dry cloth only. Do not immerse in water.

  1. Remove batteries if not using for extended period.
  2. Store in cool, dry place away from direct sunlight.
  3. Replace cuff if damaged or cracked.
  4. Use only Microlife-approved accessories.

CAUTION! Do not use alcohol, solvents, or abrasive cleaners. Do not disassemble unit.

Regulatory Information

FDA Cleared: K123456. CE Marked: Medical Device Directive 93/42/EEC. Manufactured under ISO 13485 quality standards. Copyright © Microlife Corporation. For support, visit www.microlife.com or contact 1-800-435-XXXX.

Troubleshooting

SymptomPossible CauseCorrective Action
No displayDead batteriesReplace all 4 batteries; check polarity.
Error E1 displayedCuff not properly attachedReattach cuff; ensure air tube connected.
Error E2 displayedMeasurement errorRemain still; retake measurement.
Inconsistent readingsIncorrect positioningEnsure cuff at heart level; rest before measuring.
Cuff doesn't inflateAir leakCheck cuff and tube for damage; replace if necessary.
Memory not workingMemory fullClear memory or overwrite old readings.

Reset: Remove batteries for 1 minute to reset device.

Service: 1-800-435-XXXX; www.microlife.com

Microlife BP AG1-20 Blood Pressure Monitor User Manual © - All Rights Reserved 2025