The Microlife BP B1 Standard is an automatic upper-arm blood pressure monitor designed for easy and accurate home use. It features a large, easy-to-read LCD display, one-touch operation, automatic inflation and deflation, irregular heartbeat detection, and memory storage for up to 30 readings. The device uses the oscillometric method and is clinically validated. Below are key sections for safety, features, setup, measurement, maintenance, and troubleshooting.
Key components: Main unit with LCD display, Upper-arm cuff with D-ring, Air tube, 4x AA batteries, Instruction manual, Storage case.
| Feature | Description |
|---|---|
| Automatic Inflation/Deflation | One-touch operation for easy measurement |
| Large LCD Display | Clear readout of systolic, diastolic pressure, and pulse |
| Irregular Heartbeat Detection (IHD) | Detects and indicates irregular heartbeats during measurement |
| 30 Memory Storage | Stores up to 30 readings with date and time |
| Automatic Power Off | Conserves battery life by turning off after 1 minute of inactivity |
| WHO Classification Indicator | Color-coded bar graph shows blood pressure category |
| Cuff Fit Indicator | Verifies proper cuff placement before measurement |
| Average of Last 3 Readings | Calculates and displays the average of the last three measurements |
| Clinically Validated | Meets international protocol standards for accuracy |
| Fuzzy Logic Technology | Adjusts inflation to individual user for comfort and accuracy |
Read all instructions before use. For personal home use only.
WARNING! This device is not a substitute for professional medical diagnosis. Always consult your doctor for interpretation of readings.
Unpack and verify all items are present.
CAUTION! Do not use if any item is damaged. Contact customer service.
Front Panel: LCD Display, START/STOP Button. Side: Battery Compartment. Rear: Air Tube Connector.
Display Symbols: Systolic Pressure, Diastolic Pressure, Pulse Rate, Irregular Heartbeat Symbol (heart icon with cross), Memory Symbol (M), WHO Indicator Bar, Cuff Fit Indicator (OK), Low Battery Symbol, Date/Time.
Cuff: Marked with "ARTERIA" to align with brachial artery. D-ring for secure fastening.
Prepare the monitor for first use.
Tip: Rest arm on a table so the cuff is at heart level during measurement.
For accurate results, remain still and quiet.
WARNING! Do not move or tighten muscles during measurement. Wait at least 3 minutes between readings on the same person.
After measurement, the LCD shows:
If an error occurs, an error symbol (E) with a number will flash. Refer to troubleshooting.
Stores last 30 readings with date and time.
Note: Memory is maintained when batteries are replaced if done within 2 minutes.
Unplug air tube and remove batteries before cleaning.
CAUTION! Do not attempt to repair or disassemble the device. There are no user-serviceable parts inside.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Display is blank | Batteries empty/incorrectly inserted | Replace all 4 batteries; ensure correct polarity (+/-). |
| Error Symbol "E1" | Cuff not connected or leaking | Check cuff connection; ensure cuff is wrapped tightly. |
| Error Symbol "E2" or "E3" | Measurement error (movement, irregular heartbeat) | Keep still and retry. If "E3" persists, consult physician. |
| Reading seems inaccurate | Incorrect posture or cuff position | Sit correctly with cuff at heart level. Wait 5 min of rest before measuring. |
| Memory does not store | Memory full or error | Clear memory and retake measurement. |
| Cuff does not inflate | Blocked tube or weak batteries | Straighten air tube; replace batteries. |
Reset: Remove batteries for 2 minutes, then reinsert.
Service: For technical support or service, contact Microlife customer service or visit www.microlife.com. Do not open the device.