The Microlife BP Progress is a clinically validated, automatic upper arm blood pressure monitor with advanced features including hypertension indicator, irregular heartbeat detection, memory storage for multiple users, date/time function, and WHO classification display. It provides accurate, non-invasive blood pressure and pulse rate measurements for home use. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.
Key components: Main unit with LCD display, Universal Cuff, AC Adapter, Instruction Manual, Storage Case.
| Feature | Description |
|---|---|
| Clinically Validated | Meets international accuracy standards (ESH, BHS) |
| Hypertension Indicator | Displays color-coded result based on WHO classification |
| Irregular Heartbeat Detection | Detects and displays pulse irregularity during measurement |
| Multi-User Memory | Stores up to 99 measurements for 2 users |
| Date & Time Stamp | Records measurement date and time |
| Automatic Inflation | One-touch operation with adjustable inflation |
| Average Value | Calculates average of last 3 measurements |
| Large Display | Easy-to-read backlit LCD screen |
| Universal Cuff | Fits arm circumference 22-42 cm (9-17 inches) |
| Power Options | 4x AA batteries or AC adapter |
Read all instructions before use. For home use only.
WARNING! This device is not a substitute for professional medical diagnosis. Always consult your doctor about your blood pressure.
CAUTION! Check all contents upon unpacking. Do not use if any parts are damaged.
Front Panel: START/STOP button, MEMORY button, USER button, SET button. Display: Systolic/Diastolic pressure, Pulse rate, Date/Time, User indicator, Battery indicator, Hypertension indicator (color zones).
Connections: Cuff tube connector, AC adapter socket. Cuff: Velcro closure, air tube, artery marker.
Insert batteries or connect AC adapter. Set date and time.
Tip: Use AC adapter for prolonged use to conserve batteries.
For accurate results, rest for 5 minutes before measuring.
WARNING! Do not move or talk during measurement. Ensure cuff is not too tight or loose.
Stores 99 measurements per user with date/time stamp.
Note: Memory is retained when batteries are removed.
| Display Symbol | Meaning |
|---|---|
| SYS/DIA values | Systolic/Diastolic pressure in mmHg |
| Pulse icon with value | Heart rate in beats per minute |
| Green zone | Normal blood pressure |
| Yellow zone | Mild hypertension |
| Red zone | Moderate/severe hypertension |
| Irregular heartbeat icon | Detected pulse irregularity (consult physician) |
| User 1/2 icon | Current user selection |
| Battery icon | Battery level indicator |
WHO Classification: Normal: <120/<80 mmHg; Mild: 120-139/80-89 mmHg; Moderate: 140-159/90-99 mmHg; Severe: ≥160/≥100 mmHg.
Clean device with soft, dry cloth only. Do not immerse in water.
CAUTION! Do not use alcohol, solvents, or abrasive cleaners. Do not autoclave.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Dead batteries | Replace all batteries; ensure proper polarity. |
| Error code E1 | Cuff not attached | Connect cuff properly; ensure tube not kinked. |
| Error code E2 | Measurement error | Reposition cuff; remain still; retake measurement. |
| Error code E3 | Pulse too irregular | Wait 5 minutes; retry. Consult physician if persistent. |
| Inaccurate reading | Wrong cuff position | Ensure cuff at heart level; artery marker aligned. |
| Cuff doesn't inflate | Tube blockage | Check tube connection; ensure cuff not twisted. |
| Memory not working | Memory full | Clear memory; ensure user selected correctly. |
| Display dim | Low battery | Replace batteries or use AC adapter. |
Reset: Remove batteries for 5 minutes, then reinsert.
Service: Contact authorized Microlife service center. Do not attempt repairs yourself.