The Microlife BP RM 100 is a fully automatic upper arm blood pressure monitor designed for home use. It features one-touch operation, a large LCD display with backlight, irregular heartbeat detection, 2x30 memory storage, WHO classification indicator, date and time display, automatic power-off, and a standard cuff (22-32 cm). Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.
Key components: Main unit with LCD display, Arm cuff with tube and connector, 4xAA batteries, Instruction manual, Storage case.
| Feature | Description |
|---|---|
| One-Touch Operation | Fully automatic inflation and deflation |
| WHO Classification Indicator | Color-coded display of blood pressure range |
| Irregular Heartbeat Detection | Detects and displays irregular heartbeat during measurement |
| 2x30 Memory Storage | Stores 30 measurements for each of 2 users |
| Large LCD with Backlight | Easy-to-read display for day/night use |
| Date & Time Stamp | Records measurement date and time |
| Automatic Power-Off | Conserves battery life |
| Standard Cuff (22-32 cm) | Fits most adult arms |
| Average Value | Calculates average of last 3 measurements |
| Error Detection | Alerts to incorrect cuff placement or movement |
Read all instructions before use. For accurate measurements, follow guidelines carefully.
WARNING! This device is for home use only, not for professional medical diagnosis. Always consult your doctor for medical decisions.
CAUTION! Check all items upon unpacking. Do not use if any component is damaged.
Front Panel: LCD Display, START/STOP Button, MEMORY Button, USER Button, DATE/TIME Button.
Display Symbols: Systolic pressure, Diastolic pressure, Pulse rate, WHO indicator, User indicator (1 or 2), Memory full, Irregular heartbeat, Low battery, Date/Time, Average value.
Cuff: Velcro closure, air tube connector, artery marker (align with brachial artery).
Prepare device before first use.
Tip: Rest for 5 minutes before first measurement. Avoid eating, smoking, or exercising 30 minutes prior.
For accurate results, follow proper procedure.
WARNING! Do not move or talk during measurement. Ensure cuff is at heart level.
Results display with WHO classification colors.
| WHO Category | Systolic (mmHg) | Diastolic (mmHg) | Display Color |
|---|---|---|---|
| Optimal | < 120 | < 80 | Green |
| Normal | 120-129 | 80-84 | Green |
| High Normal | 130-139 | 85-89 | Yellow |
| Grade 1 Hypertension | 140-159 | 90-99 | Orange |
| Grade 2 Hypertension | 160-179 | 100-109 | Red |
| Grade 3 Hypertension | ≥ 180 | ≥ 110 | Red (flashing) |
Irregular Heartbeat Symbol: Appears if irregular rhythm detected during measurement. Consult physician if frequent.
Device stores 30 measurements for each of 2 users.
Note: Memory full symbol appears when 30 readings stored. Oldest reading overwritten when new one added.
Proper care ensures accurate measurements and long device life.
CAUTION! Do not use alcohol or solvents. Do not expose to extreme temperatures.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Dead batteries | Replace all 4 batteries with new ones |
| Error code E1 | Cuff not properly attached | Check cuff connection; reattach firmly |
| Error code E2 | Measurement error | Remain still; retake measurement |
| Error code E3 | Pressure too high | Check cuff placement; consult physician |
| Inconsistent readings | Wrong cuff position | Ensure cuff at heart level; rest before measuring |
| Memory not working | Wrong user selected | Press USER button to select correct user |
| Cuff doesn't inflate | Tube blockage or leak | Check tube connection; ensure no kinks |
| Irregular heartbeat symbol | Arrhythmia detected | Consult physician if symbol appears frequently |
Reset: Remove batteries for 5 minutes, then reinsert to reset device.
Service: For technical support, contact Microlife Customer Service at 1-800-xxx-xxxx or visit www.microlife.com