Microlife BP RM 100 Blood Pressure Monitor User Manual

The Microlife BP RM 100 is a fully automatic upper arm blood pressure monitor designed for home use. It features one-touch operation, a large LCD display with backlight, irregular heartbeat detection, 2x30 memory storage, WHO classification indicator, date and time display, automatic power-off, and a standard cuff (22-32 cm). Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Safety Information 3. Package Contents 4. Device Overview 5. First-Time Setup 6. Taking a Measurement 7. Understanding Results 8. Memory Function 9. Care & Maintenance 10. Technical Specifications 11. Troubleshooting

Features at a Glance

Key components: Main unit with LCD display, Arm cuff with tube and connector, 4xAA batteries, Instruction manual, Storage case.

FeatureDescription
One-Touch OperationFully automatic inflation and deflation
WHO Classification IndicatorColor-coded display of blood pressure range
Irregular Heartbeat DetectionDetects and displays irregular heartbeat during measurement
2x30 Memory StorageStores 30 measurements for each of 2 users
Large LCD with BacklightEasy-to-read display for day/night use
Date & Time StampRecords measurement date and time
Automatic Power-OffConserves battery life
Standard Cuff (22-32 cm)Fits most adult arms
Average ValueCalculates average of last 3 measurements
Error DetectionAlerts to incorrect cuff placement or movement

Safety Information

Read all instructions before use. For accurate measurements, follow guidelines carefully.

  1. Consult your physician before use if you have arrhythmia, pre-eclampsia, or other conditions.
  2. Do not use on infants, children, or persons unable to express themselves.
  3. Do not use during blood dialysis or if you have a shunt in your arm.
  4. Wait at least 5 minutes between consecutive measurements on the same person.
  5. Do not use in explosive atmospheres or near strong electromagnetic fields.

WARNING! This device is for home use only, not for professional medical diagnosis. Always consult your doctor for medical decisions.

Package Contents

CAUTION! Check all items upon unpacking. Do not use if any component is damaged.

Device Overview

Front Panel: LCD Display, START/STOP Button, MEMORY Button, USER Button, DATE/TIME Button.

Display Symbols: Systolic pressure, Diastolic pressure, Pulse rate, WHO indicator, User indicator (1 or 2), Memory full, Irregular heartbeat, Low battery, Date/Time, Average value.

Cuff: Velcro closure, air tube connector, artery marker (align with brachial artery).

First-Time Setup

Prepare device before first use.

  1. Insert batteries: Open battery compartment, insert 4xAA batteries observing polarity.
  2. Set date and time: Press DATE/TIME button, use START/STOP to adjust values.
  3. Select user: Press USER button to select User 1 or User 2.
  4. Apply cuff: Wrap cuff on bare upper arm, 1-2 cm above elbow, align artery marker.

Tip: Rest for 5 minutes before first measurement. Avoid eating, smoking, or exercising 30 minutes prior.

Taking a Measurement

For accurate results, follow proper procedure.

  1. Sit comfortably with back supported and feet flat on floor.
  2. Place arm on table with palm up, cuff at heart level.
  3. Press START/STOP button - device inflates automatically.
  4. Remain still and quiet during measurement.
  5. Results display automatically with systolic, diastolic, and pulse rate.
  6. Device deflates and stores reading in memory.
  7. To turn off, press START/STOP again or wait for auto power-off.

WARNING! Do not move or talk during measurement. Ensure cuff is at heart level.

Understanding Results

Results display with WHO classification colors.

WHO CategorySystolic (mmHg)Diastolic (mmHg)Display Color
Optimal< 120< 80Green
Normal120-12980-84Green
High Normal130-13985-89Yellow
Grade 1 Hypertension140-15990-99Orange
Grade 2 Hypertension160-179100-109Red
Grade 3 Hypertension≥ 180≥ 110Red (flashing)

Irregular Heartbeat Symbol: Appears if irregular rhythm detected during measurement. Consult physician if frequent.

Memory Function

Device stores 30 measurements for each of 2 users.

  1. Select user: Press USER button to choose User 1 or User 2.
  2. View memory: Press MEMORY button to scroll through stored readings.
  3. Average value: Displays average of last 3 measurements for selected user.
  4. Clear memory: Hold MEMORY button for 5 seconds to delete all readings for current user.

Note: Memory full symbol appears when 30 readings stored. Oldest reading overwritten when new one added.

Care & Maintenance

Proper care ensures accurate measurements and long device life.

CAUTION! Do not use alcohol or solvents. Do not expose to extreme temperatures.

Technical Specifications

Troubleshooting

SymptomPossible CauseCorrective Action
No displayDead batteriesReplace all 4 batteries with new ones
Error code E1Cuff not properly attachedCheck cuff connection; reattach firmly
Error code E2Measurement errorRemain still; retake measurement
Error code E3Pressure too highCheck cuff placement; consult physician
Inconsistent readingsWrong cuff positionEnsure cuff at heart level; rest before measuring
Memory not workingWrong user selectedPress USER button to select correct user
Cuff doesn't inflateTube blockage or leakCheck tube connection; ensure no kinks
Irregular heartbeat symbolArrhythmia detectedConsult physician if symbol appears frequently

Reset: Remove batteries for 5 minutes, then reinsert to reset device.

Service: For technical support, contact Microlife Customer Service at 1-800-xxx-xxxx or visit www.microlife.com