The Microlife BP W150 IMT is an upper arm blood pressure monitor with IntelliSense MAM (Microlife Average Mode) technology for accurate measurement, irregular heartbeat detection, 2-user memory (60 measurements each), date/time display, automatic inflation, WHO blood pressure classification indicator, and large LCD display. It features one-touch operation, adjustable cuff (22-42 cm), and operates on 4 AA batteries or AC adapter. Below are key sections for safety, features, setup, measurement, maintenance, and troubleshooting.
Key components: Main unit with LCD display, adjustable upper arm cuff, air tube, 4 AA batteries, AC adapter port, START/STOP button, MEMORY button.
| Feature | Description |
|---|---|
| IntelliSense MAM Technology | Automatically takes 3 consecutive measurements for average result |
| 2-User Memory | Stores 60 measurements per user with date/time stamp |
| WHO Classification Indicator | Color-coded display shows blood pressure category |
| Irregular Heartbeat Detection (IHB) | Detects pulse irregularities during measurement |
| Automatic Inflation | Inflates to optimal pressure with gentleFit technology |
| Adjustable Cuff | Fits arm circumference 22-42 cm (8.7-16.5 inches) |
| Large LCD Display | Shows systolic/diastolic pressure, pulse, date/time |
| One-Touch Operation | Simple START/STOP button for easy use |
| Power Options | 4 AA batteries or AC adapter (included in some models) |
| Automatic Power Off | Conserves battery life after 1 minute of inactivity |
Read all instructions before use. For personal home use only.
WARNING! Not for use with pacemakers or other electronic implants without medical consultation. Do not use if cuff is damaged.
Unpack and verify all components are present.
CAUTION! Do not pull on air tube when disconnecting from main unit. Use only Microlife-approved accessories.
Prepare device for first use.
Tip: For most accurate results, wait 5 minutes after battery installation before first measurement.
For accurate results, follow these steps carefully.
WARNING! Do not inflate cuff when not wrapped around arm. Maximum 3 consecutive measurements with 2-minute rest between.
Device stores 60 measurements for each of 2 users.
Note: Memory is maintained when batteries are replaced if done within 2 minutes.
WHO Classification Indicator: Color-coded bar graph shows:
Irregular Heartbeat Detection (IHB):
Clean device with soft, dry cloth only. Do not use liquids or chemicals.
CAUTION! Do not autoclave, sterilize, or expose to high temperatures. Keep away from children.
| Display | Meaning | Action |
|---|---|---|
| E1 | Cuff not properly attached or leakage | Check cuff connection; rewrap cuff |
| E2 | Pressure over 300 mmHg during inflation | Remove cuff; restart measurement |
| E3 | Pulse signal too weak or irregular | Reposition cuff; remain still; retry |
| E4 | Too many pulse irregularities | Wait 5 minutes; retry; consult doctor if persistent |
| E5 | Measurement error | Restart device; replace batteries |
| Lo | Low battery | Replace all 4 batteries |
| --- | No display | Check batteries; ensure device is on |
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No power/display | Dead batteries, incorrect installation | Replace all 4 AA batteries; check polarity |
| Inaccurate readings | Wrong cuff position, movement during measurement | Reposition cuff at heart level; remain still |
| Cuff doesn't inflate | Air leak, tube not connected | Check cuff for damage; ensure tube clicked in |
| Memory not working | Batteries removed too long | Memory cleared if batteries out >2 minutes |
| Error messages persist | Device malfunction | Reset device (remove batteries 5 minutes); contact service |
| Display faint/unreadable | Low battery, extreme temperatures | Replace batteries; use at 10-40°C only |
Reset: Remove batteries for 5 minutes, then reinstall.
Service: For technical support, contact Microlife customer service at 1-800-566-0466 or visit www.microlife.com. Do not attempt to repair device yourself.