The Microlife BP W90 is a fully automatic upper arm blood pressure monitor with clinically validated accuracy, irregular heartbeat detection, 2-user memory (60 measurements each), WHO classification indicator, one-touch operation, adjustable cuff (22-42 cm), large LCD display with backlight, date/time function, and automatic averaging of last 3 readings. Powered by 4xAA batteries or optional AC adapter. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.
Key components: Main unit with LCD display, adjustable upper arm cuff, AC adapter port, battery compartment, START/STOP button, MEMORY button, USER button.
| Feature | Description |
|---|---|
| Clinically Validated Accuracy | Meets international protocols (ESH, BHS, AAMI) |
| Irregular Heartbeat Detection (IHD) | Detects and displays pulse irregularity during measurement |
| 2-User Memory | Stores 60 measurements per user with date/time stamp |
| WHO Classification Indicator | Color-coded display shows blood pressure category |
| Automatic 3-Reading Average | Calculates average of last 3 consecutive readings |
| Adjustable Cuff (22-42 cm) | Fits standard to large adult arms |
| Large LCD with Backlight | Easy-to-read display in all lighting conditions |
| One-Touch Operation | Automatic inflation and deflation |
| Date & Time Function | Automatic timestamp for all measurements |
| Battery/AC Power | 4xAA batteries or optional AC adapter |
Read all instructions before use. For personal home use only.
WARNING! Not for medical diagnosis. Consult healthcare professional for interpretation. Do not overtighten cuff.
Note: Optional AC adapter sold separately (Model AD-12).
Front Panel: LCD display, START/STOP button, MEMORY button, USER button.
Display Symbols: Systolic/Diastolic pressure, Pulse rate, WHO indicator (color bars), User icon (1/2), Memory icon, Battery icon, Irregular heartbeat symbol, Date/Time, Average icon.
Side/Back: AC adapter port, cuff connector, battery compartment.
Cuff: Velcro closure, air tube, artery marker (align with brachial artery).
First-time preparation and settings.
CAUTION! Use correct cuff size. Too small/large cuff affects accuracy. Arm circumference must be 22-42 cm.
Proper measurement procedure for accurate results.
Tip: Take measurements at same time daily for consistent tracking.
Two independent user memories with 60 measurements each.
Note: Memory full indicator (FULL) appears when 60 measurements stored. Oldest reading is overwritten.
Color-coded display based on World Health Organization guidelines.
| Color Zone | Blood Pressure Category | Systolic/Diastolic Range |
|---|---|---|
| Blue | Optimal | < 120 / < 80 mmHg |
| Green | Normal | 120-129 / 80-84 mmHg |
| Yellow | High Normal | 130-139 / 85-89 mmHg |
| Orange | Grade 1 Hypertension | 140-159 / 90-99 mmHg |
| Red | Grade 2 Hypertension | 160-179 / 100-109 mmHg |
| Flashing Red | Grade 3 Hypertension | ≥ 180 / ≥ 110 mmHg |
Important: This indicator is for reference only. Always consult physician for diagnosis.
Proper care ensures accuracy and longevity.
CAUTION! Do not immerse in water. Avoid extreme temperatures (>40°C or <10°C).
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Dead batteries | Replace all 4 batteries with fresh alkaline batteries. |
| Error Code E1 | Cuff not attached | Ensure cuff connector is properly inserted. |
| Error Code E2 | Cuff pressure error | Check cuff for leaks/kinks; reposition correctly. |
| Error Code E3 | Measurement error | Remain still during measurement; retake after 2 minutes. |
| Inconsistent readings | Incorrect posture/cuff position | Sit correctly with arm at heart level; ensure proper cuff placement. |
| IHD symbol appears | Irregular heartbeat detected | Wait 2 minutes and retake; consult physician if frequent. |
| Memory full | 60 measurements stored | Clear memory or device overwrites oldest reading. |
| Weak batteries symbol | Low battery power | Replace all batteries promptly. |
Reset: Remove batteries for 5 minutes to reset device.
Service: Do not attempt repair. Contact Microlife service center: 1-800-566-0456 or www.microlife.com