The Microlife BP3AQ1-1 is an upper arm blood pressure monitor featuring Microlife's patented AFIB detection technology, which can screen for atrial fibrillation during measurement. It offers one-touch operation, a large LCD display with backlight, memory storage for multiple users, irregular heartbeat detection, WHO blood pressure classification indicator, and an adjustable cuff. Below are key sections for safety, features, setup, measurement, memory functions, maintenance, and troubleshooting.
Key components: Main unit with LCD display, Adjustable upper arm cuff, AC adapter port, Memory function buttons, START/STOP button.
| Feature | Description |
|---|---|
| AFIB Detection | Screens for possible atrial fibrillation during measurement |
| WHO Indicator | Color-coded display shows blood pressure classification |
| Memory Storage | Stores readings for up to 2 users (99 readings each) |
| Irregular Heartbeat Detection | Detects and displays irregular heartbeat during measurement |
| Large LCD Display | Easy-to-read backlit display with date/time |
| Adjustable Cuff | Fits arm circumferences 22-42 cm (8.7-16.5 inches) |
| One-Touch Operation | Simple START/STOP button for easy use |
| Automatic Power Off | Conserves battery life |
| Average Value | Calculates average of last 3 measurements |
| Date & Time Stamp | Records measurement date and time |
Read all instructions before use. For accurate measurements and safe operation:
WARNING! This device is for home use only, not for professional medical diagnosis. Consult your physician for medical advice.
Unpack and verify all components are present.
CAUTION! Do not use if any components are damaged. Contact customer service for replacement.
Front Panel: LCD display, START/STOP button, MEMORY button, USER button, SET button.
Display Symbols: Systolic pressure, Diastolic pressure, Pulse rate, AFIB symbol, Irregular heartbeat symbol, WHO indicator, User indicator, Memory full indicator, Battery indicator, Date/Time.
Side/Back: AC adapter port, Cuff connector, Battery compartment.
Prepare device for first use.
Tip: For most accurate results, use AC adapter instead of batteries.
For accurate readings, follow these steps carefully.
WARNING! Do not move or talk during measurement. Ensure cuff is at heart level for accurate results.
The display shows systolic pressure, diastolic pressure, and pulse rate.
| Display Symbol | Meaning |
|---|---|
| AFIB Symbol | Possible atrial fibrillation detected - consult physician |
| Irregular Heartbeat Symbol | Irregular heartbeat detected during measurement |
| Green WHO Zone | Normal blood pressure |
| Yellow WHO Zone | Mild hypertension |
| Orange WHO Zone | Moderate hypertension |
| Red WHO Zone | Severe hypertension |
Note: AFIB detection is a screening tool, not a diagnosis. Always consult your physician.
Store and review measurements for two users.
Tip: Take measurements at the same time each day for consistent tracking.
Proper care ensures accurate measurements and long device life.
CAUTION! Do not wash cuff in washing machine. Do not expose device to extreme temperatures or humidity.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Dead batteries | Replace all 4 batteries with new ones |
| Error E1 displayed | Cuff not properly attached | Check cuff connection; ensure tube is securely plugged in |
| Error E2 displayed | Cuff pressure error | Check cuff for leaks or damage; replace if necessary |
| Inconsistent readings | Incorrect cuff position | Ensure cuff is at heart level; retake measurement |
| AFIB symbol appears | Possible atrial fibrillation | Consult your physician for evaluation |
| Memory full | 99 readings stored | Clear memory or overwrite old readings |
Reset: Remove batteries for 5 minutes to reset device.
Service: For technical support, contact Microlife customer service or visit www.microlife.com