Microlife BP3GX1-5A Blood Pressure Monitor User Manual
The Microlife BP3GX1-5A is an automatic upper-arm blood pressure monitor designed for home use. It features a large, easy-to-read LCD display, one-touch operation, irregular heartbeat detection, 2-user memory with 60 measurements each, date and time display, automatic averaging of the last 3 readings, and WHO classification indicator. It is clinically validated for accuracy and powered by 4 AA batteries or an optional AC adapter. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.
Features at a Glance
Key components: Main unit with LCD display, Upper-arm cuff with D-ring, AC adapter port, Battery compartment, START/STOP button, MEMORY button.
| Feature | Description |
| One-Touch Operation | Automatic inflation and deflation at the press of a button |
| WHO Indicator | Color-coded bar graph showing blood pressure classification |
| Irregular Heartbeat Detection | Detects and displays an icon for pulse irregularities during measurement |
| 2 x 60 Memory | Stores 60 measurements for each of two users with date and time |
| 3-Time Average | Automatically calculates the average of the last 3 consecutive readings |
| Large LCD Display | Easy-to-read digits and icons |
| Automatic Power Off | Conserves battery life by turning off after 1 minute of inactivity |
| Cuff Fit Indicator | Verifies if the cuff is wrapped correctly before measurement |
| Date & Time | Built-in clock for timestamping measurements |
| Clinically Validated | Meets international protocols for accuracy (ESH, AAMI) |
Safety Information
Read all instructions before use. For accurate measurements and safe operation.
- Intended Use: For non-invasive measurement of systolic and diastolic blood pressure and pulse rate from the upper arm of adult patients in home environments.
- Contraindications: Do not use on an arm with an intravenous drip or arterial shunt.
- Precautions: Do not use the device near strong electromagnetic fields (e.g., mobile phones, microwave ovens).
- Batteries: Use only 4 AA (1.5V) alkaline batteries. Remove batteries if the device will not be used for an extended period.
- Cuff Care: Do not twist or fold the cuff tube excessively. Do not wash the cuff.
WARNING! This device is not a substitute for professional medical diagnosis. Consult your physician for interpretation of results and treatment decisions.
Package Contents
- Microlife BP3GX1-5A Blood Pressure Monitor (Main Unit)
- Upper-Arm Cuff (22-42 cm circumference)
- 4 x AA Batteries
- Instruction Manual
- Quick Start Guide
- Storage Case
Note: Check that all items are present. Do not use if any part appears damaged.
Device Overview
Front Panel: LCD Display, START/STOP Button, MEMORY Button, User Select Icon (1/2).
Display Symbols: Systolic Pressure, Diastolic Pressure, Pulse Rate, WHO Indicator Bar, User Icon, Memory Icon, Battery Icon, Irregular Heartbeat Icon, Date/Time, Average Icon, Cuff Error Icon.
Side/Rear: Cuff Socket, AC Adapter Socket (DC 6V), Battery Compartment Cover.
Cuff: Cloth cuff with Velcro, metal D-ring, air tube, and artery marker.
Initial Setup
Before first use, install batteries and set the date and time.
- Insert Batteries: Open the battery compartment on the back. Insert 4 AA batteries, observing correct polarity (+/-). Close the cover.
- Set Date & Time: Press and hold the MEMORY button for 3 seconds until the year flashes. Use START/STOP to change value and MEMORY to confirm and move to month, day, hour, and minute.
- Select User: Briefly press MEMORY to toggle between User 1 and User 2 icon on the display.
- Connect Cuff: Plug the cuff tube firmly into the socket on the side of the device.
CAUTION! Do not mix old and new batteries. Do not use rechargeable batteries unless specified.
Taking a Measurement
For the most accurate results, rest for 5 minutes before measuring. Avoid eating, smoking, or exercising 30 minutes prior.
- Apply the Cuff: Sit comfortably with feet flat on the floor. Place cuff on bare left upper arm. The artery marker (▼) should align with your brachial artery. Secure with Velcro so it is snug but not tight.
- Position Arm: Rest your arm on a table so the cuff is at heart level. Relax your palm upward.
- Start Measurement: Press the START/STOP button. The device will check cuff fit, then inflate automatically.
- Remain Still: Do not move or talk during inflation and measurement.
- Read Results: After deflation, your systolic, diastolic pressure, and pulse rate will display along with the WHO indicator. The device will automatically store the reading for the selected user.
- Power Off: The device turns off automatically after 1 minute.
Tip: Take measurements at the same time each day for consistent tracking.
Understanding Your Results
The LCD displays three main values and a classification bar.
- Systolic Pressure (top number): Pressure in arteries when the heart beats.
- Diastolic Pressure (bottom number): Pressure in arteries when the heart rests between beats.
- Pulse Rate (heart icon): Number of heartbeats per minute.
- WHO Indicator: A colored bar graph shows classification:
- Green (Optimal/Normal): Systolic < 130, Diastolic < 85
- Yellow (High Normal/Mild Hypertension): Systolic 130-159, Diastolic 85-99
- Red (Moderate/Severe Hypertension): Systolic ≥ 160, Diastolic ≥ 100
- Irregular Heartbeat Icon: If this symbol appears, it may indicate an irregular pulse rhythm. Consult your physician if it appears frequently.
Memory Function
The device stores 60 measurements for each of two users with date and time.
- Select User: Press MEMORY briefly to choose User 1 or User 2 before taking a measurement.
- Recall Memory: Press and hold the MEMORY button for 2 seconds while the device is off. The most recent reading displays. Press MEMORY repeatedly to scroll through all stored readings for that user.
- View Average: After scrolling through all readings, the display will show "AVG" followed by the average of the last 3 consecutive measurements taken within 10 minutes of each other.
- Clear Memory: To delete all memory for the selected user, press and hold both START/STOP and MEMORY buttons for 5 seconds while in memory recall mode. "CLr" will flash.
Care & Maintenance
Unplug the AC adapter (if used) and remove batteries before cleaning.
- Cleaning: Wipe the main unit with a soft, slightly damp cloth. Do not use solvents or abrasives. Do not immerse in water.
- Cuff: Clean the cuff with a cloth dampened with mild soapy water. Do not machine wash, dry clean, or iron. Let it air dry completely.
- Storage: Store the device and cuff in the provided case in a cool, dry place. Avoid extreme temperatures and humidity.
- Batteries: Replace batteries when the low battery icon appears on the display. Remove batteries if the device will not be used for 3 months or more.
CAUTION! Never attempt to repair the device yourself. Contact Microlife service for any repairs.
Specifications
- Measurement Method: Oscillometric
- Measurement Range: Pressure: 0-299 mmHg, Pulse: 40-199 beats/min
- Accuracy: Pressure: ±3 mmHg, Pulse: ±5% of reading
- Cuff Size: 22 - 42 cm (8.7" - 16.5") upper arm circumference
- Memory: 2 x 60 measurements with date & time
- Power Supply: 4 x 1.5V AA batteries or DC 6V/500mA AC adapter (optional)
- Automatic Shut-off: Approx. 1 minute after measurement
- Dimensions (Main Unit): Approx. 128mm (W) x 98mm (H) x 141mm (D)
- Weight (without batteries): Approx. 300g
- Operating Conditions: 10°C to 40°C, 15% to 90% relative humidity (non-condensing)
Troubleshooting
| Symptom | Possible Cause | Corrective Action |
| Display is blank | Batteries depleted or incorrectly inserted | Replace all 4 batteries with new ones, ensuring correct polarity. |
| Error Code "E" appears | Cuff not connected, leaking, or wrapped incorrectly | Check cuff connection. Re-wrap cuff snugly. Ensure tube is not kinked. |
| Error Code "Err" appears | Measurement error (movement, irregular heartbeat) | Remain still and relaxed. Repeat measurement. If persistent, consult a doctor. |
| Inaccurate reading | Incorrect posture, cuff position, or recent activity | Rest for 5 mins. Ensure cuff is at heart level and fits properly. Repeat. |
| Memory does not store | Memory full or wrong user selected | Clear memory for the current user. Ensure correct user icon is selected before measuring. |
| Device does not inflate | Blocked air tube or internal fault | Check tube for kinks. If problem persists, contact Microlife service. |
Reset: Remove batteries for 1 minute to perform a full reset.
Service & Support: For technical support or service, visit www.microlife.com or contact your local Microlife distributor.