The Microlife BP3MC1-PC is an upper-arm digital blood pressure monitor with PC connectivity, featuring Microlife's patented AFIB detection technology, Intellisense for comfortable inflation, memory storage for multiple users, large LCD display, irregular heartbeat detection, date/time function, and USB interface for data transfer to compatible software. It is clinically validated for accuracy and intended for home use. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.
Key components: Main unit with LCD display, Adjustable arm cuff, USB cable, AC adapter, Storage case, Quick start guide.
| Feature | Description |
|---|---|
| AFIB Detection | Patented technology to screen for atrial fibrillation during measurement |
| Intellisense | Automatic inflation to optimal pressure for comfortable measurement |
| PC Connectivity | USB port for transferring readings to health management software |
| Multi-User Memory | Stores readings for up to 2 users (99 readings each) |
| Irregular Heartbeat Detection | Alerts if an irregular heartbeat is detected during measurement |
| Large LCD Display | Shows systolic, diastolic, pulse, date/time, and user indicator |
| Date & Time Stamp | Automatically records date and time with each reading |
| Automatic Power Off | Conserves battery life by turning off after 1 minute of inactivity |
| WHO Indicator | Color-coded bar graph classifying blood pressure according to WHO guidelines |
| Clinically Validated | Meets international protocols for accuracy (ESH, BHS, AAMI) |
Read all instructions before use. For home use only.
WARNING! This device is not a substitute for professional medical diagnosis. Consult your doctor for interpretation of readings.
CAUTION! Inspect all contents. Do not use if any part appears damaged.
Front Panel: LCD Display, START/STOP Button, MEMORY Button, USER Button (1/2), DATE/TIME Button.
Side Panel: USB Port, DC Input Jack (for AC adapter).
Cuff: Air tube connector, Velcro closure, artery marker (△).
Display Symbols: User indicator (1/2), Systolic/Diastolic/Pulse values, AFIB symbol, Irregular Heartbeat symbol, Battery indicator, Memory full icon, WHO color bar.
Power on device; set date and time.
Tip: For more stable power, use the included AC adapter by plugging into DC input jack.
For most accurate results, measure at the same time each day.
WARNING! Do not inflate cuff when not wrapped around arm. Avoid taking measurements immediately after eating, drinking caffeine, or smoking.
Device stores 99 readings per user (2 users total).
Note: For long-term tracking, transfer readings to PC software via USB.
Transfer readings to Microlife Health Management Software (sold separately) or compatible third-party software.
Tip: Software allows tracking trends, printing reports, and sharing data with healthcare providers.
Clean only with a soft, dry cloth. Do not immerse in water or use solvents.
CAUTION! Never attempt to repair the device yourself. Contact authorized service.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Dead batteries | Replace all 4 batteries; ensure correct polarity. |
| Error Code "E1" | Cuff not connected or leakage | Check cuff connection; ensure cuff is tightly wrapped. |
| Error Code "E2" | Measurement error | Remain still and retake measurement; check cuff position. |
| Inconsistent readings | Body movement, talking | Take measurement in quiet environment without moving. |
| AFIB symbol flashes | Possible atrial fibrillation detected | Consult your physician with reading. Take multiple measurements. |
| Irregular heartbeat symbol | Irregular rhythm during measurement | Remain calm and retake. If persistent, consult physician. |
| USB not recognized | Driver/software issue | Reinstall software; try different USB port; ensure device is on. |
Reset: Remove batteries and AC adapter for 1 minute, then reinsert.
Service: For technical support, visit www.microlife.com or contact your local Microlife service center.