The Microlife BPB2 Basic is an automatic upper arm blood pressure monitor designed for home use. It features one-touch operation, a large LCD display with backlight, irregular heartbeat detection, hypertension indicator, memory storage for up to 30 readings with date and time stamp, WHO blood pressure classification indicator, and automatic power-off. Powered by 4 AA batteries or optional AC adapter. Below are key sections for safety, features, setup, measurement, maintenance, and troubleshooting.
Key components: Main unit with LCD display, Arm cuff with D-ring, AC adapter port, Battery compartment, START/STOP button, MEMORY button.
| Feature | Description |
|---|---|
| One-Touch Operation | Automatic inflation and deflation with single button press |
| Large LCD Display | Clear readout of systolic, diastolic pressure, pulse rate |
| Backlight | Illuminates display for low-light conditions |
| Irregular Heartbeat Detection | Detects and displays symbol for irregular pulse during measurement |
| Hypertension Indicator | Displays color-coded bar according to WHO classification |
| Memory Function | Stores up to 30 readings with date and time |
| Automatic Power-Off | Conserves battery life by turning off after 1 minute of inactivity |
| User Profiles | Supports two separate user memory banks |
| WHO Classification | Shows result category (Optimal, Normal, High Normal, etc.) |
| Average Reading | Calculates average of last 3 measurements taken within 10 minutes |
Read all instructions before use. For personal home use only.
WARNING! This device is not a substitute for professional medical diagnosis. Always consult your physician about your blood pressure.
Unpack and verify all components are present.
Note: Batteries and AC adapter are not included in standard package (sold separately).
Front: LCD display, START/STOP button. Side: MEMORY button, AC adapter port. Bottom: Battery compartment.
Display Symbols: Systolic pressure, Diastolic pressure, Pulse rate, Irregular heartbeat symbol, Hypertension indicator bar, User indicator (1 or 2), Memory full indicator, Low battery symbol, Date and time.
Cuff: Cloth cuff with Velcro closure, air tube connector, artery marker (align with brachial artery).
Prepare device for first use.
CAUTION! Use only recommended batteries. Remove batteries if device will not be used for extended period.
For accurate results, follow these steps carefully.
Tip: Take measurements at same time each day for consistent tracking.
The display shows systolic pressure (higher number), diastolic pressure (lower number), and pulse rate.
| WHO Category | Systolic (mmHg) | Diastolic (mmHg) | Indicator Bar Color |
|---|---|---|---|
| Optimal | < 120 | < 80 | Green |
| Normal | 120-129 | 80-84 | Light Green |
| High Normal | 130-139 | 85-89 | Yellow |
| Grade 1 Hypertension | 140-159 | 90-99 | Orange |
| Grade 2 Hypertension | 160-179 | 100-109 | Red |
| Grade 3 Hypertension | ≥ 180 | ≥ 110 | Flashing Red |
Irregular Heartbeat Symbol: Appears if irregular pulse detected during measurement. Consult physician if symbol appears frequently.
Device stores last 30 readings for each user (60 total).
Note: Memory full indicator appears when 30 readings are stored. Oldest reading is overwritten by new one.
Proper care ensures accurate measurements and device longevity.
CAUTION! Do not autoclave, sterilize, or expose to high temperatures. Do not attempt to repair device yourself.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Dead batteries | Replace all 4 batteries with new ones |
| Error code E1 | Cuff not connected properly | Check cuff connection; ensure tube is fully inserted |
| Error code E2 | Cuff pressure error | Check cuff for leaks or damage; reposition cuff |
| Error code E3 | Measurement error | Remain still during measurement; retake reading |
| Inconsistent readings | Incorrect positioning | Ensure arm is at heart level; cuff is correctly positioned |
| Device turns off during measurement | Low batteries | Replace batteries immediately |
| Memory not storing | Memory full | Delete old readings or memory is corrupted |
| Display symbols unclear | Low battery | Replace batteries; display may dim when batteries are low |
Reset: Remove batteries for 5 minutes, then reinsert to reset device.
Service: For technical support, contact Microlife Customer Service at 1-800-566-3456 or visit www.microlife.com