Microlife BPB6 Connect Blood Pressure Monitor User Manual
The Microlife BPB6 Connect is a clinically validated, fully automatic upper arm blood pressure monitor with Bluetooth connectivity, irregular heartbeat detection, MAM (Microlife Average Mode) technology for increased accuracy, large backlit display, adjustable cuff (22-42 cm), 2-user memory with 200 measurements each, WHO hypertension indicator, and data transfer to the Microlife Connected Health app. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.
Features at a Glance
Key components: Main unit with large LCD display, adjustable upper arm cuff, air tube, 4x AA batteries, instruction manual, and quick start guide.
| Feature | Description |
| Bluetooth Connectivity | Wirelessly syncs measurements to the Microlife Connected Health app |
| MAM Technology | Takes 3 consecutive measurements and calculates the average for higher accuracy |
| Irregular Heartbeat Detection (IHD) | Detects and indicates possible pulse irregularities during measurement |
| WHO Hypertension Indicator | Color-coded bar graph shows classification according to WHO guidelines |
| 2-User Memory | Stores up to 200 measurements for each of two users with date and time |
| Adjustable Cuff | Fits arm circumferences from 22 cm to 42 cm (9" to 16.5") |
| Large Backlit Display | Easy-to-read results, even in low light conditions |
| Automatic Power Off | Conserves battery life by turning off after 1 minute of inactivity |
| Date & Time Stamp | Records the time and date of each measurement in memory |
| Battery/AC Operation | Powered by 4 AA batteries or optional AC adapter (not included) |
Safety Information
Read all instructions before use. For accurate measurements, remain still and seated.
- Intended Use: For non-invasive measurement of systolic and diastolic blood pressure and pulse rate from the upper arm of adult patients in home environments.
- Contraindications: Not for use on infants, children, or patients with pre-eclampsia. Consult a physician if you have an arrhythmia.
- Precautions: Do not use near strong electromagnetic fields (e.g., mobile phones, microwave ovens). Do not inflate cuff when not wrapped around arm.
- Battery Safety: Use only recommended batteries. Remove batteries if device will not be used for an extended period.
WARNING! This device is not a substitute for professional medical diagnosis. Consult your physician for interpretation of results and treatment decisions.
Package Contents
- Microlife BPB6 Connect Blood Pressure Monitor (Main Unit)
- Adjustable Upper Arm Cuff (22-42 cm)
- Air Tube (permanently attached to cuff)
- 4 x AA Batteries
- Instruction Manual (this document)
- Quick Start Guide
- Warranty Card
CAUTION! Inspect all contents upon unboxing. Do not use if any part appears damaged.
Device Overview
Front Panel (Display & Controls):
- START/STOP Button: Initiates and stops measurement.
- M Button: Accesses memory mode to review past readings.
- User Button (1/2): Selects User 1 or User 2 profile.
- Bluetooth Button: Manages connection to the smartphone app.
- LCD Display: Shows systolic/diastolic pressure, pulse rate, icons for user, memory, Bluetooth, IHD, battery, and WHO indicator.
Side/Back: Battery compartment, AC adapter port (covered by cap), air tube connector.
Cuff: Velcro closure, metal D-ring, correct positioning marker (artery symbol).
Initial Setup
Prepare the device for first use.
- Insert Batteries: Open battery compartment on back, insert 4 AA batteries observing correct polarity (+/-).
- Connect Cuff: Plug the air tube from the cuff firmly into the port on the side of the monitor.
- Set Date & Time: Press and hold the M button for 3 seconds. Use START/STOP to adjust values and User buttons to navigate. Press START/STOP to confirm.
- Select User: Briefly press the User 1 or User 2 button to assign your profile. The corresponding icon will appear on the display.
Tip: Rest for 5 minutes before taking your first measurement. Avoid caffeine, exercise, and smoking for 30 minutes prior.
Taking a Measurement
For the most accurate results, follow these steps carefully.
- Prepare: Sit comfortably on a chair with back support. Rest for 5 minutes. Place feet flat on the floor and do not cross legs.
- Apply Cuff: Bare your left arm. Slide cuff onto arm so the tube runs down the center of your inner arm. Position the cuff edge 2-3 cm above your elbow. The artery marker (◯) should be over your brachial artery. Secure with Velcro snugly, but not too tight.
- Position Arm: Rest your arm on a table so the cuff is at heart level. Relax your hand with palm facing up.
- Start Measurement: Press the START/STOP button. The cuff will inflate automatically. Remain still and quiet until measurement is complete and cuff deflates.
- Read Results: Your systolic pressure, diastolic pressure, and pulse rate will display. The WHO indicator bar will show your classification (e.g., Optimal, Normal, High). An Irregular Heartbeat symbol (❤️ with *) will flash if detected.
- MAM Mode (Optional): For a more accurate average, the device will automatically begin a series of 3 measurements 1 minute apart after the first reading. Stay seated with the cuff on.
WARNING! Do not move or talk during inflation and measurement.
Using the Memory Function
The device stores the last 200 measurements for each user with date and time.
- View Memory: Press the M button. The display shows the most recent reading for the selected user.
- Scroll: Press the START/STOP button to scroll backwards through the memory. Press the User button to jump to the oldest reading.
- Exit Memory: Press the M button again or wait 60 seconds to return to standby mode.
- Clear Memory: To delete all data for the current user, enter memory mode, scroll to the oldest reading, then press and hold the User button for 5 seconds until "CLr" appears.
Note: Memory is retained when batteries are removed.
Bluetooth Connectivity
Sync your data with the Microlife Connected Health app (available for iOS and Android).
- Download the "Microlife Connected Health" app from the App Store or Google Play.
- Enable Bluetooth on your smartphone.
- On the monitor, press the Bluetooth button. The Bluetooth icon will flash, indicating it is discoverable.
- Open the app and follow the on-screen instructions to pair with "BPB6-XXXX".
- Once paired, future measurements will be automatically sent to the app for tracking, history charts, and sharing with your doctor.
Troubleshooting Connection: Ensure the monitor is within 3 meters (10 feet) of your phone. Restart the app and monitor if pairing fails.
Care & Maintenance
Unplug the air tube and remove batteries before cleaning.
- Cleaning: Wipe the monitor and cuff with a soft, slightly damp cloth. Do not immerse in water or use abrasive cleaners, alcohol, or solvents.
- Storage: Store in a cool, dry place. Do not store with the cuff tightly wrapped or bent.
- Cuff Care: Check the cuff and tube periodically for cracks or leaks. Do not fold the tube sharply.
- Batteries: Replace all 4 batteries when the low battery icon appears. Use alkaline batteries for best performance.
CAUTION! Do not attempt to disassemble or repair the monitor. There are no user-serviceable parts inside.
Technical Specifications
- Measurement Method: Oscillometric
- Measurement Range: Pressure: 0 - 299 mmHg, Pulse: 40 - 199 beats/min
- Accuracy: Pressure: ±3 mmHg, Pulse: ±5% of reading
- Cuff Size: 22 - 42 cm arm circumference
- Memory: 2 x 200 measurements with date & time
- Bluetooth: Version 4.0, range up to 10 m (33 ft)
- Power Supply: 4 x 1.5V AA batteries or 6V DC/600mA AC adapter (optional)
- Auto Shut-off: Approx. 1 minute after last button press
- Operating Conditions: 10°C to 40°C (50°F to 104°F), 15% to 90% relative humidity (non-condensing)
- Dimensions (Monitor): Approx. 128 mm (W) x 98 mm (H) x 141 mm (D)
- Weight (with batteries): Approx. 350 g
Troubleshooting
| Symptom | Possible Cause | Corrective Action |
| Display is blank | Batteries dead/incorrectly inserted | Replace all 4 batteries; ensure correct polarity. |
| Error Code "E" appears | Cuff not connected or air leak | Check cuff connection; ensure cuff is wrapped snugly. Replace cuff if torn. |
| Error Code "Err" appears | Measurement error | Remain still and retry. Ensure cuff is at heart level. |
| Bluetooth icon not flashing | Pairing mode not active | Press and hold Bluetooth button for 3 seconds to enter pairing mode. |
| Inconsistent readings | Incorrect posture or cuff position | Follow measurement steps precisely. Ensure cuff size is correct for your arm. |
| Device does not turn off | Button may be stuck | Remove batteries for 1 minute, then reinsert. |
Reset: Remove batteries for 5 minutes to perform a full reset. Date, time, and memory will be retained.
Service: For technical support or service, visit www.microlife.com or contact your local Microlife distributor. Do not open the device.
Microlife BPB6 Connect Blood Pressure Monitor User Manual © - All Rights Reserved 2025