The Microlife BPM 1 is an automatic upper arm blood pressure monitor designed for home use. It features one-touch operation, a large LCD display, irregular heartbeat detection, and memory storage for multiple users. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.
Key components: Main unit with LCD display, Arm cuff with tube and connector, Instruction manual, Storage case, Batteries.
| Feature | Description |
|---|---|
| One-Touch Operation | Automatic inflation and measurement |
| Large LCD Display | Clear readout of systolic, diastolic, pulse |
| Irregular Heartbeat Detection | Detects and indicates irregular heartbeats during measurement |
| Memory Function | Stores readings for multiple users |
| Automatic Power Off | Conserves battery life |
| WHO Classification Indicator | Color-coded bar graph shows blood pressure category |
| Cuff Fit Indicator | Ensures proper cuff placement |
| Date & Time Stamp | Records measurement time |
Read all instructions before use.
WARNING! This device is not a substitute for professional medical diagnosis. If readings are consistently abnormal, consult your doctor.
CAUTION! Check all contents upon unpacking. Do not use if any part is damaged.
Front Panel: START/STOP button, MEMORY button, USER button (1/2), LCD display.
Display Symbols: Systolic pressure, Diastolic pressure, Pulse rate, Irregular heartbeat symbol, Battery indicator, Memory indicator, Cuff fit indicator, WHO classification bar.
Connector Port: For cuff tube connection on side of device.
Tip: Wait 5 minutes after physical activity or eating before first measurement.
WARNING! Do not move or talk during measurement. Ensure cuff is not too tight or loose.
Systolic (upper number): Pressure when heart beats. Diastolic (lower number): Pressure when heart rests between beats.
| WHO Category | Systolic (mmHg) | Diastolic (mmHg) | Display Color |
|---|---|---|---|
| Optimal | < 120 | < 80 | Green |
| Normal | 120-129 | 80-84 | Yellow |
| High Normal | 130-139 | 85-89 | Orange |
| Hypertension | ≥ 140 | ≥ 90 | Red |
Irregular heartbeat symbol appears if irregular rhythm detected during measurement.
Stores up to 60 readings per user (30 each for User 1 and User 2).
Note: Memory is retained when batteries are replaced if done within 2 minutes.
CAUTION! Remove batteries if device will not be used for extended period. Do not mix old and new batteries.
Remove batteries before cleaning. Wipe device with slightly damp cloth. Do not immerse in water.
Cuff Care: Wipe with mild soap solution. Do not machine wash. Do not twist tube.
Storage: Store in provided case in cool, dry place. Do not store with cuff tightly wrapped.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Dead batteries | Replace all 4 batteries. |
| Error code E1 | Cuff not properly connected | Check cuff tube connection. |
| Error code E2 | Cuff over-inflated | Remove cuff and restart measurement. |
| Error code E3 | Measurement error | Ensure proper cuff position and remain still. |
| Inconsistent readings | Wrong cuff position or movement | Follow measurement procedure exactly. |
| Memory not working | Batteries removed too long | Replace batteries within 2 minutes to retain memory. |
Service: For technical support, contact Microlife Customer Service at 1-800-xxx-xxxx or visit www.microlife.com.