The Microlife BR W3 Comfort is an upper-arm blood pressure monitor featuring Microlife's patented AFIB detection technology, MAM (Microlife Average Mode) for more accurate readings, a large backlit display, adjustable cuff (22-42 cm), irregular heartbeat detection, WHO indicator, memory for up to 200 readings with date/time stamp, and one-touch operation. Powered by 4xAA batteries or AC adapter. Below are key sections for safety, features, setup, measurement, maintenance, and troubleshooting.
Key components: Main unit with large LCD display, adjustable upper-arm cuff, AC adapter port, battery compartment, START/STOP button, MEMORY button, MAM button.
| Feature | Description |
|---|---|
| AFIB Detection | Patented technology to detect possible atrial fibrillation |
| MAM Mode | Average Mode for taking 3 consecutive readings with automatic average calculation |
| WHO Indicator | Color-coded bar graph based on WHO blood pressure classification |
| Memory Function | Stores up to 200 readings with date and time stamp |
| Adjustable Cuff | Fits arm circumferences from 22 to 42 cm |
| Large Backlit Display | Easy-to-read LCD with backlight for low-light conditions |
| Irregular Heartbeat Detection | Detects and displays irregular heartbeat during measurement |
| One-Touch Operation | Simple START/STOP button for easy use |
| Automatic Power Off | Conserves battery life by turning off after 1 minute of inactivity |
| Dual Power Source | Operates on 4xAA batteries or included AC adapter |
Read all instructions before use. Keep for future reference.
WARNING! Not suitable for persons with arrhythmias other than atrial fibrillation. Consult physician if irregular heartbeat symbol appears frequently.
NOTE: Check all items are present before use. Contact retailer if anything is missing.
Front Panel: Large LCD display, START/STOP button, MEMORY button, MAM button.
Display Symbols: Systolic/Diastolic pressure, Pulse rate, WHO indicator, AFIB symbol, Irregular heartbeat symbol, Memory indicator, Battery indicator, Date/Time.
Side/Back: AC adapter port, battery compartment, cuff connector.
Cuff: Velcro closure, air tube, artery marker (align with brachial artery).
Prepare device for first use.
CAUTION! Use only recommended batteries and AC adapter. Do not mix old and new batteries.
For accurate results, follow these steps carefully.
Tip: Take measurements at same time each day for consistent tracking.
Device stores up to 200 readings with date/time.
NOTE: Memory preserved during battery change for approximately 1 hour.
MAM provides more accurate average by taking 3 consecutive readings.
Medical Recommendation: MAM mode recommended by hypertension societies for home monitoring.
Patented technology screens for possible atrial fibrillation during measurement.
WARNING! Device may not detect all cases of AFIB. Regular medical check-ups essential.
Proper care ensures accurate measurements and long device life.
CAUTION! Do not disassemble device. No user-serviceable parts inside.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Dead batteries | Replace all 4 batteries; check polarity. |
| Error E1 displayed | Cuff not connected properly | Check cuff connection; reinsert tube. |
| Error E2 displayed | Cuff pressure too high | Remove and reapply cuff; ensure not too tight. |
| Error E3 displayed | Movement during measurement | Remain still; retake measurement. |
| Inconsistent readings | Incorrect cuff position | Ensure cuff at heart level; follow measurement guidelines. |
| AFIB symbol frequent | Possible arrhythmia | Consult healthcare professional. |
| Cuff doesn't inflate | Tube blockage/leak | Check tube for kinks; ensure proper connection. |
Reset: Remove batteries for 1 minute to reset device.
Service: Contact Microlife customer service or authorized service center. Do not attempt repair yourself.