Microlife BR W3 Comfort Blood Pressure Monitor User Manual

The Microlife BR W3 Comfort is an upper-arm blood pressure monitor featuring Microlife's patented AFIB detection technology, MAM (Microlife Average Mode) for more accurate readings, a large backlit display, adjustable cuff (22-42 cm), irregular heartbeat detection, WHO indicator, memory for up to 200 readings with date/time stamp, and one-touch operation. Powered by 4xAA batteries or AC adapter. Below are key sections for safety, features, setup, measurement, maintenance, and troubleshooting.

1. Features at a Glance 2. Safety Information 3. Package Contents 4. Device Overview 5. Initial Setup 6. Taking a Measurement 7. Memory Function 8. MAM Mode (Average Mode) 9. AFIB Detection 10. Care & Maintenance 11. Troubleshooting

Features at a Glance

Key components: Main unit with large LCD display, adjustable upper-arm cuff, AC adapter port, battery compartment, START/STOP button, MEMORY button, MAM button.

FeatureDescription
AFIB DetectionPatented technology to detect possible atrial fibrillation
MAM ModeAverage Mode for taking 3 consecutive readings with automatic average calculation
WHO IndicatorColor-coded bar graph based on WHO blood pressure classification
Memory FunctionStores up to 200 readings with date and time stamp
Adjustable CuffFits arm circumferences from 22 to 42 cm
Large Backlit DisplayEasy-to-read LCD with backlight for low-light conditions
Irregular Heartbeat DetectionDetects and displays irregular heartbeat during measurement
One-Touch OperationSimple START/STOP button for easy use
Automatic Power OffConserves battery life by turning off after 1 minute of inactivity
Dual Power SourceOperates on 4xAA batteries or included AC adapter

Safety Information

Read all instructions before use. Keep for future reference.

  1. Do not use for medical diagnosis without consulting a healthcare professional.
  2. Do not use on infants, children, or persons unable to express themselves.
  3. Do not use during physical activity or immediately after exercise.
  4. Do not inflate cuff when not wrapped around arm.
  5. Keep device away from electromagnetic fields (microwaves, mobile phones).

WARNING! Not suitable for persons with arrhythmias other than atrial fibrillation. Consult physician if irregular heartbeat symbol appears frequently.

Package Contents

NOTE: Check all items are present before use. Contact retailer if anything is missing.

Device Overview

Front Panel: Large LCD display, START/STOP button, MEMORY button, MAM button.

Display Symbols: Systolic/Diastolic pressure, Pulse rate, WHO indicator, AFIB symbol, Irregular heartbeat symbol, Memory indicator, Battery indicator, Date/Time.

Side/Back: AC adapter port, battery compartment, cuff connector.

Cuff: Velcro closure, air tube, artery marker (align with brachial artery).

Initial Setup

Prepare device for first use.

  1. Insert batteries: Open battery compartment, insert 4xAA batteries observing polarity.
  2. Set date and time: Press and hold MEMORY button for 3 seconds, use START/STOP to adjust.
  3. Connect cuff: Plug air tube into connector on side of device until it clicks.
  4. AC adapter (optional): Plug into port on side and into wall outlet.

CAUTION! Use only recommended batteries and AC adapter. Do not mix old and new batteries.

Taking a Measurement

For accurate results, follow these steps carefully.

  1. Sit quietly for 5 minutes before measuring.
  2. Wrap cuff on bare upper arm, 1-2 cm above elbow. Artery marker over brachial artery.
  3. Rest arm on table with cuff at heart level. Keep feet flat, back supported.
  4. Press START/STOP button. Cuff inflates automatically.
  5. Remain still and quiet during measurement.
  6. Reading displays with systolic, diastolic, pulse rate, and WHO indicator.
  7. Device automatically deflates and stores reading.

Tip: Take measurements at same time each day for consistent tracking.

Memory Function

Device stores up to 200 readings with date/time.

  1. View memory: Press MEMORY button to scroll through stored readings.
  2. Delete single reading: While viewing reading, press and hold MEMORY for 3 seconds.
  3. Delete all memory: In memory mode, press and hold both MEMORY and START/STOP for 5 seconds.
  4. Memory full: Oldest reading automatically deleted when memory exceeds 200.

NOTE: Memory preserved during battery change for approximately 1 hour.

MAM Mode (Average Mode)

MAM provides more accurate average by taking 3 consecutive readings.

  1. Prepare as for normal measurement.
  2. Press MAM button instead of START/STOP.
  3. Device takes 3 readings automatically with 30-second intervals.
  4. Final display shows average of all 3 readings.
  5. All 3 individual readings stored in memory.

Medical Recommendation: MAM mode recommended by hypertension societies for home monitoring.

AFIB Detection

Patented technology screens for possible atrial fibrillation during measurement.

WARNING! Device may not detect all cases of AFIB. Regular medical check-ups essential.

Care & Maintenance

Proper care ensures accurate measurements and long device life.

  1. Clean cuff with damp cloth only. Do not immerse in water.
  2. Clean device with dry soft cloth. No solvents or abrasives.
  3. Store in provided case in cool, dry place.
  4. Remove batteries if not using for extended period.
  5. Replace batteries when low battery symbol appears.

CAUTION! Do not disassemble device. No user-serviceable parts inside.

Troubleshooting

SymptomPossible CauseCorrective Action
No displayDead batteriesReplace all 4 batteries; check polarity.
Error E1 displayedCuff not connected properlyCheck cuff connection; reinsert tube.
Error E2 displayedCuff pressure too highRemove and reapply cuff; ensure not too tight.
Error E3 displayedMovement during measurementRemain still; retake measurement.
Inconsistent readingsIncorrect cuff positionEnsure cuff at heart level; follow measurement guidelines.
AFIB symbol frequentPossible arrhythmiaConsult healthcare professional.
Cuff doesn't inflateTube blockage/leakCheck tube for kinks; ensure proper connection.

Reset: Remove batteries for 1 minute to reset device.

Service: Contact Microlife customer service or authorized service center. Do not attempt repair yourself.