The Microlife CVS BP3KX1-1B is an automatic upper arm blood pressure monitor with clinically validated accuracy, irregular heartbeat detection, 2-user memory (60 readings each), risk category indicator, date/time display, and one-touch operation. It features a large LCD display, adjustable cuff (22-42 cm), and is powered by 4 AA batteries or optional AC adapter. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.
Key components: Main unit with LCD display, Adjustable arm cuff, Air tube, 4 AA batteries, Instruction manual, Storage case.
| Feature | Description |
|---|---|
| Automatic Inflation/Deflation | One-touch operation for easy measurement |
| Clinically Validated Accuracy | Meets international protocol standards |
| Irregular Heartbeat Detection | Detects and displays irregular heartbeat during measurement |
| 2-User Memory (60 readings each) | Stores readings for two users separately |
| Risk Category Indicator | Color-coded display shows WHO hypertension classification |
| Date & Time Stamp | Records measurement date and time |
| Adjustable Cuff (22-42 cm) | Fits standard to large adult arms |
| Large LCD Display | Easy-to-read results with backlight |
| Battery/AC Power | 4 AA batteries or optional AC adapter |
| Automatic Power Off | Conserves battery life |
Read all instructions before use. Keep for future reference.
WARNING! This device is not a substitute for professional medical diagnosis. Consult your physician for interpretation of readings.
Note: Check all items upon unpacking. Contact retailer if anything is missing or damaged.
Front Panel: LCD display, START/STOP button, MEMORY button, USER SELECT button, DATE/TIME SET button.
Display Symbols: User indicator (1/2), Systolic pressure, Diastolic pressure, Pulse rate, Irregular heartbeat symbol, Risk category indicator (color bars), Battery indicator, Memory full indicator, Date/Time, Error codes.
Cuff Components: Arm cuff with Velcro closure, Air tube connector, Artery marker (align with brachial artery).
Before first use: Install batteries and set date/time.
Tip: Use fresh alkaline batteries for best performance. Remove batteries if not using for extended periods.
For accurate results, follow these steps carefully:
Important: Take measurements at same time each day for consistent tracking. Avoid talking or moving during measurement.
The device stores 60 readings for each of 2 users.
Note: Memory is maintained when batteries are replaced if done within 2 minutes.
Proper care ensures accurate measurements and long device life.
CAUTION! Do not disassemble or attempt to repair device. Contact authorized service center.
FDA Cleared: K number [insert if applicable]. CE Marked: Medical Device Directive 93/42/EEC. Manufactured under ISO 13485 quality standards. This device complies with Part 15 of FCC Rules. Copyright © Microlife Corporation. For support, visit www.microlife.com or contact customer service at 1-888-396-2880.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Dead batteries | Replace all 4 batteries with fresh alkaline batteries. |
| Error E1 displayed | Cuff not properly attached | Check cuff connection to main unit; ensure tube not kinked. |
| Error E2 displayed | Cuff pressure error | Remove and reapply cuff; ensure proper positioning. |
| Error E3 displayed | Measurement error | Remain still during measurement; retake after 5 minutes rest. |
| Inconsistent readings | Improper cuff position | Ensure cuff at heart level; follow measurement instructions carefully. |
| Irregular heartbeat symbol flashes | Irregular rhythm detected | Consult physician if symbol appears frequently. |
| Memory full | 60 readings stored per user | Clear memory or overwrite oldest readings. |
| Weak inflation | Low batteries or air leak | Replace batteries; check cuff and tube for damage. |
Reset: Remove batteries for 2 minutes to reset device.
Service: 1-888-396-2880; www.microlife.com