The Microlife WatchBP Office BP 3SK1-3B is a professional-grade, clinically validated blood pressure monitor designed for office and professional use. It features AFIB detection, MAM (Microlife Average Mode) technology for enhanced accuracy, large memory storage, adjustable cuff sizes, clear LCD display, and USB connectivity for data transfer. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.
Key components: Main unit with LCD display, adjustable arm cuff, air tube, AC adapter, USB cable, and user manual.
| Feature | Description |
|---|---|
| AFIB Detection | Detects atrial fibrillation during measurement |
| MAM Technology | Automatically takes 3 consecutive readings and calculates the average |
| Large Memory | Stores up to 99 readings with date and time |
| Adjustable Cuff | Fits arm circumferences 22-42 cm (standard cuff included) |
| Clear LCD Display | Shows systolic, diastolic, pulse, and irregular heartbeat symbol |
| USB Connectivity | For data transfer to PC software (optional) |
| WHO Classification | Color-coded indicator based on WHO hypertension guidelines |
| Automatic Power Off | Conserves battery life |
| Date & Time Stamp | Records measurement time automatically |
| Clinically Validated | Meets international protocols for accuracy |
Read all instructions before use. For accurate measurements and safety:
WARNING! This device is for professional use only. Not for continuous monitoring. Do not disassemble or modify.
Unpack and verify all components are present.
CAUTION! Do not use if any component is damaged. Contact customer service for replacement.
Front Panel: LCD display, START/STOP button, MEMORY button, MAM button, SET button. Rear: USB port, AC adapter port, battery compartment.
Display Symbols: Systolic/Diastolic values, Pulse rate, AFIB indicator, MAM mode, Memory full, Battery low, WHO classification bar, Date/Time.
Buttons: START/STOP (begin/end measurement), MEMORY (review stored readings), MAM (activate average mode), SET (configure date/time).
Power on device; configure basic settings.
Tip: For most accurate results, rest for 5 minutes before first measurement.
Follow these steps for accurate readings:
Note: AFIB symbol appears if irregular heartbeat is detected. Consult physician if this occurs frequently.
MAM (Microlife Average Mode) provides the most accurate reading by averaging 3 consecutive measurements.
Important: Remain seated and keep cuff on throughout all 3 measurements for accurate averaging.
Device stores up to 99 readings with date and time stamp.
Tip: Regular data transfer helps track patient blood pressure trends over time.
Proper care ensures accurate measurements and device longevity.
CAUTION! Do not autoclave or sterilize any part of the device. Do not use near flammable gases.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Dead batteries | Replace batteries or use AC adapter |
| Error code E1 | Cuff not connected properly | Check air tube connection |
| Error code E2 | Cuff pressure error | Check for leaks; replace cuff if damaged |
| Inconsistent readings | Movement during measurement | Remain still; repeat measurement |
| Memory full | 99 readings stored | Transfer data to PC or clear memory |
| AFIB symbol appears | Irregular heartbeat detected | Consult physician for evaluation |
| USB not connecting | Driver/software issue | Install latest software from Microlife website |
Reset: Remove batteries and AC adapter for 5 minutes to reset device.
Service: Do not attempt to repair. Contact authorized service center: 1-800-431-1871 or visit www.microlife.com